background image

Nielsen-Kellerman

610.447.1555

www.nkhome.com

[email protected]

Instruction Manual for Kestrel 4100 version: 4.01 ALL

19

Data Display and 

Storage

Minimum, maximum, average and logged history stored and displayed for every 

measured value. 480-point data logger with graphical display. Auto data storage; interval 

settable from 2 seconds to 12 hours. Manual data capture.  

Display Digits

Multifunction, multi-digit programmable dot-matrix display.

Display Update

1 second

Display Languages

English, French, German, Italian, Spanish

Display Backlight

Aviation green electroluminescent backlight.  Automatic or manual operation.

Operational 

Temperature Range

The operational temperature range of the liquid crystal display and batteries is 0° F to 

131° F / -18 °C to 55 °C.  Beyond the limits of this range, the unit must be maintained 

within range and exposed for minimum time necessary to take reading.

Storage Temperature

-22 °F to 140 °F / -30 °C to 60 °C

Auto Shutdown

User-selectable:  15 minutes, 60 minutes or disabled

Batteries

AAA Alkaline, two, included.  Average life, 400 hours of use, +/-depending on backlight 

use.

Sealing

Waterproof (IP69 standard)

Dimensions

5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm

Weight

3.6 oz / 102 gm

Color

Safety orange.

18

Measurement

Units

Operational

Range

Resolution

Accuracy 

(+/-)

Specification Range

Temperature

°F

-50.0 to 260.0

0.1

1.8

-20 to 158

1 minute  

°C

-45.0 to 125.0

0.1

1

-2 to 70 °C

Relative Humidity

%RH

0.0 to 100.0

0.1

3.0 %RH

5 to 95 % non condensing

1 minute  

Wind Chill  

°F

0.7 to 135.0 MPH, -

50.0 to 260.0 °F

0.1

1.8

1.8 to 89 MPH, -20 to 158 °F

1 second  

°C

0.4 to 60.0 m/s, -45.0 

to 125.0 °C

0.1

1

0.4 to 40 m/s, -29 to 70 °C

Dewpoint  

°F

0.0 to 100.0 %RH, -

50.0 to 260.0 °F

0.1

3.6

-20 to 158 °F, 20 to 95% RH

1 minute  

°C

0.0 to 100.0 %RH, -

45.0 to 125.0 °C

0.1

2

-29 to 70 °C, 20 to 95 %RH

Heat Index  

°F

0.0 to 100.0 %RH, -

50.0 to 260.0 °F

0.1

3.6

-20 to 158 °F, 20 to 95% RH

1 minute  

°C

0.0 to 100.0 %RH, -

45.0 to 125.0 °C

0.1

2

-29 to 70 °C, 20 to 95 %RH

Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074).  

Response specification is time to achieve 95% or better of stated accuracy. Calibration drift +/- 2% over 24 months. Relative humidity may 

be recalibrated at factory or in field using Kestrel Humidity Calibration Kit, PN-0824.

The above values are calculated from the primary measurements of wind speed, temperature and relative humidity. 

Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible.

Measurement  

Units

Operational

Range

Resolution

Accuracy

(+/-)

Specification

Range

Response Time  

Air Velocity

MPH

0.8 to 135.0

0.1

0.8 to 89.0 MPH

1 second  

fpm

59 to 11,948

1

59 to 7877

Knots

0.6 to 118.3

0.1

0.6 to 78

Beaufort

0 to 12

1

0 to 12

m/s

0.4 to 60.0

0.1

0.4 to 40.0 m/s

KPH

1.0

0.1

1.0 to 144

Air Flow

cfm

0 to 99,999

1

0 to 99,999

1 second  

m

3

/h

0 to 99,999

1

0 to 99,999

m

3

/m

0 to 99,999

1

0 to 99,999

m

3

/s

0 to 99,999

0.1

0 to 99,999

L/s

0 to 99,999

1

0 to 99,999

3% of

reading

3% of

reading

1 inch diameter impeller with precision axle and sapphire bearings, individually tested in NIST-traceable wind tunnel.  Calibration 

drift < 1% after 100 hours use at 16 MPH / 7 m/s.  Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may 

cause destruction of impeller.  Replacement impeller, PN-0801, may be field-installed without tools (US Patent 5,783,753).

17

Reviews: