12
C.2 lighting Procedures
1. Broiler is
centered under
hood and
plugged in
2. Gas valve is
open when
handle is in line
(parallel to) the
pipe
3. Turn ventilation
system on
The JF93 is equipped with automatic ignition. When the broiler is turned on, a hot surface ignitor turns on 5 seconds
before the flow of gas. Gas then flows to all of the burners. If the burners are not lit within 10 seconds, the control will
reset and try again for 10 seconds. This occurs 3 times. If the broiler does not light after the third attempt, the ignition
failure light will flash and the main on/off switch must be cycled to repeat the procedure. If this still doesn’t light the
broiler, see the MANUAL IGNITION instructions.
WaRnInG
THe VenTIlaTIon sYsTeM MUsT
be on aT all TIMes DURInG
bRoIleR oPeRaTIon. oPeRaT-
InG bRoIleR WITHoUT PRoPeR
VenTIlaTIon Is a seVeRe fIRe
HaZaRD.
noRMal IGnITIon
PRe-lIGHTInG PRePaRaTIon
Nieco Corporation - Model JF93G
1. Turn the
MaIn PoWeR sWITCH
on.
1.
2.
2. Allow broiler to heat for 45 minutes before cooking.