Nidek Medical Mark 5 Nuvo 10 User Manual Download Page 6

2010-2324CE Rev A

6

November 2013

     

to 105

o

F) operation.

 •  Storage temperature from -20

o

C to 60

o

C (0

o

to 140

o

F).

 •  Relative humidity of between 15 % and 95 % operation  

  and storage, both non-condensing. 

 •  Altitude(21

o

C): Up to 1500m (5000ft) without degrada-

     tion; Consult your equipment provider for further infor

     mation regarding 1500 m to 4000m (5000 to 13000ft). 

 

•  Complies with EN60601-1 standard; spilling of a glass 

     of water.  

IV. 7. Standards

ISO 8359:1996 Oxygen concentrators for medical use.

EN 60601-1[UL60601-1:2003],CAN/CSA-C22.2 No.601.1-

M90 w/A1&A2: Electrical Safety- Medical Devices.

EN60601-1-2:2000  Electromagnetic Compatibility

                                                                                                                                                                  

I

V.8. Method for disposing of waste

All waste from the 

Mark 5 Nuvo MB

 (patient circuit, filter, 

etc.) must be disposed of using the methods appropriate to 

the civil authority of the location where disposed.    

IV.9. Method for disposing of the device

In order to preserve the environment, the concentrator must 

only be disposed of using the appropriate methods.  All ma-

terials of construction are recycleable.

Furthermore, as part of the marking (directive 93/42/EEC), 

the serial number of the device disposed of must be sent to 

the 

Nidek

 

Medical

 technical service department if the unit 

has the          marking.

Accuracy of flow supplied:

I

n compliance with the ISO 8359 standard, the flow supplied 

is equal to the flow set on the flowmeter, accurate to within  ± 

10% or 200 ml/min, whichever is the larger of the two.

Average oxygen content:

5 1/min, 8 l/min, 10 1/min:  90%. +5.5% / -3.0%

(Values at 21

o

C and at one atmosphere pressure).

Minimum recommended flow: 1 l/min on 5L unit, 2 l/min 

on 8 & 10L units.

Maximum recommended flow: 5 l/min, 8 l/min or 10 l/min 

model specific.

The variation of the maximum recommended flow does not 

exceed ± 10 % of the indicated value when a back pressure 

of 6.9 kPa (1 psig) is applied to the output of the device. The 

maximum outlet pressure is: 7psig for 5 l/min, 15 psig for 8 

l/min, and 20 psig for 10 l/min.

Electrical  power  supply:                                                                                                                                                                                     

                                                                                                            

5 l/min Model:

 

115 V Units 

230 V Units 

Frequency: 

  60Hz 

  50/60Hz

 

Average Power:  

   410 watts 

  420 watts

Protection Class:  

  Class II 

  Class II

Mains Protection: 

  10A 

  5A                                                                                                                                          

 

                                                                                                                                                     

8

 l/min Model:

             

115 V Units 

230 V Units 

Frequency: 

  60Hz 

  50/60Hz

 

Average Power:  

   490 watts 

  490 watts

Protection Class:  

  Class II 

  Class II

Mains Protection: 

  10A 

  5A

 

                                                                                                                                                     

10 l/min Model:

            

115 V Units 

230 V Units 

Frequency: 

   60Hz                      50/60Hz

 

                          

Average Power:  

    700 watts               490/585 watts

Protection Class:  

   Class II                   Class II

Mains Protection: 

   10A                        5A

                                                                                                                                               

                                                                                                               

Filters:

At the rear of the device: a cabinet air filter.

At the compressor input: an inlet air filter, behind cabinet 

air filter.   

Before  the  oxygen  outlet:  a  final  product  filter  <  0.3  µm. 

(technician only)

Air circulation:

 

One tubeaxial fan cools the compressor compartment and a 

second fan cools the heat exchanger coil on 8 & 10 lpm models. 

.

Environmental limit conditions:

The performance of the device (especially the oxygen concen

-

tration) are quoted at 21

o

C (70

o

F) and one atmosphere. They 

may change with temperature and altitude. For further infor

-

mation, please consult the maintenance manual.

 •  The device must be stored, transported and used in the  

  vertical position only.

 •  Ambient temperature of between 10

o

C and  40

o

C (50

o

                                                                                                     

Nuvo 

Serial No. ___________________________

Date first used: 

 ___________________________

_________________________________________

Maintained by:  ___________________________

_________________________________________

Your distributor:  _________________________

Address :  ________________________________

_________________________________________

_________________________________________

Telephone  :  ______________________________

Summary of Contents for Mark 5 Nuvo 10

Page 1: ...3 III CLEANING MAINTENANCE 4 III 1 Cleaning 4 III 2 Everyday disinfection 4 III 3 Maintenance 4 IV USEFUL INFORMATION 4 IV 1 Accessories and spare parts 4 IV 2 Materials in direct indirect contact wi...

Page 2: ...r installer or distributor are not considered to be responsible themselves for the consequences on the safety reliability and characteristics of a device unless Theassembly fitting extensions adjustme...

Page 3: ...of the correct voltage and frequency as defined on the manufacturer s technical label 8 f Press the power switch I 0 to the ON position I The green indicator will light when the oxygen concentration e...

Page 4: ...ons The cabinet air filter should be washed or replaced The entire oxygen administration circuit oxygen therapy nasal cannulas etc must be changed III 3 Maintenance No special maintenance needs to be...

Page 5: ...angle transport with humidifier fitted 70o Weight 24 kg 54 lbs Noise level within ISO 8359 guidelines Flow values Continuously Adjustable Flowmeter 1 to 5 2 to 8 or 2 to 10 depending on model IV 5 3...

Page 6: ...the maximum recommended flow does not exceed 10 of the indicated value when a back pressure of 6 9 kPa 1 psig is applied to the output of the device The maximum outlet pressure is 7psig for 5 l min 15...

Page 7: ...vice provider for any updates to recommended schedules The work must be carried out by suitably trained technicians certified by the manufacturer Use original spare parts only see Pg 8 Uponrequest the...

Page 8: ...in the I ON position but the green indicator is not lighted Faulty indicator Contact your equipment supplier The I 0 ON OFF button is in the I ON position but there is no flow The audible alarm sound...

Page 9: ...November 2013 2010 2324CE Rev A 9 V EMC Electromagnetic Statements...

Page 10: ...010 2324CE Rev A 10 November 2013 NOTES...

Page 11: ...November 2013 2010 2324CE Rev A 11 NOTES...

Page 12: ...alley East Industrial Drive Birmingham Alabama 35217 U S A Tel 205 856 7200 Fax 205 856 0533 EU Representative mdi Europa GmbH Langenhagener Str 71 30855 Hannover Langenhagen Germany Tel 49 511 39 08...

Reviews: