19.85
: Trigger 2 holding time
Adjustment range : 00 to 59
Factory setting
: 00
Format
: 8-bit
Used to set how long the trigger circuit 2
output is held in active state (1).
The unit of time is set by parameter
19.86
.
19.86
: Trigger 2 unit holding time
Adjustment range : Second (0), Minute (1),
Hour (2)
Factory setting
: Second (0)
Format
: 8-bit
Used to set the unit of time used to define how
long the trigger circuit 2 output is held in active
state (1).
Second (0):
The holding time
19.85
is expressed in
seconds.
Minute (1):
The holding time
19.85
is expressed in
minutes.
Hour (2):
The holding time
19.85
is expressed in
hours.
Note:
Do not set the unit to “hour (2)” if the
trigger mode is “hourly (2)”.
19.87
: Trigger 2 destination
Adjustment range :
00.00
to
21.51
Factory setting
:
00.00
Format
: 16-bit
Used to select the ‘bit’ parameter on which
trigger circuit 2 will act.
19.88
: Datalogger
Adjustment range : Stop (0), Run (1), Single (2)
Factory setting : Stop (0)
Format
: 8-bit
Used to select the appropriate operating
mode.
Stop (0):
Used to stop storage at any time. The memory
card can only be removed in this mode.
CAUTION:
The LED* must be off before the SD card is
removed.
Run (1):
The selected variables are stored
continuously. A file is created each time the
trigger conditions are fulfilled. The file name
and format are identical to those in “Single”
mode (2). The number of storage operations is
only limited by the memory card capacity.
Note:
If a trigger condition is present but the
previous storage operation has not finished, it
is not taken into account.