background image

10

PREVENTIVE MAINTENANCE 

Installation guide FFB brake motors

5286 en - 2017.09 / c

5 - PREVENTIVE MAINTENANCE 

Before any intervention or operation for 

preventive or corrective maintenance, please, 

download NECESSARILY the update version of 

Maintenance guide reference 5287:

  

www.leroy-somer.com

Consult Leroy-Somer (www.leroy-somer.com: Services/Drive 

systems) who in its continuous search for ways to help our 

customers, has evaluated numerous methods of preventive 

maintenance.

6 - USE IN EXAT ZONE 22

Special marking (EXAT) 

 (§1.1):

FFB250NU001 

Mf :  

52 Nm 

S N° : 9999999/001 

U :  180 VDC 

I :  345 mA 

Motor size : 168 

Nmax :  3600 rpm 

II 3 D Ex tc IIIB T125°C Dc 

FFB 3 

6.5 kg

             

II 3D Ex tc IIIB

: Group II, category 3, non-

conductive dusts.

T125°C

 : température maximale de surface.

Dc

: equipment protection level.

Nmax 3600 rpm

 : maximum rotation speed in 

Exat.

The brake must be assembled with a motor which respects 

the same EXAT level requirements at least.

If  the  brake  is  not  equipped  with  a  release/application 

indicator,  check  the  clearance  periodically  according  to 

the rates and the energy to be dissipated on each braking 

operation (see technical catalogue ref 5329 § Operation).

Those persons required to work on electrical installations and 

equipment in zones where there is a risk of explosion must be 

specially trained in the necessary skills.

In  effect,  they  must  be  familiar  not  only  with  the  electrical 

risks,  but  also  with  those  that  are  due  to  the  chemical 

properties  and  physical  characteristics  of  products  used  in 

the installation (gas, vapour, dust), as well as the environment 

in which the equipment operates. These elements dictate the 

risk of fire and explosion.

In particular, they must be informed and aware of the specific 

safety reasons and requirements in order to adhere to them.

For example:

- do not open when powered up, 

- do  not  open  when  powered  up  in  atmospheres 

D21containing explosive dust, 

- do not repair when powered up,

- do not manoeuvre when on load,

- wait several minutes before opening,

- replace the seals tightly to ensure watertightness.

Summary of Contents for LEROY-SOMER FFB

Page 1: ...en Installation guide Brake motors FFB Before any intervention or operation for preventive or corrective maintenance please download NECESSARILY the update version of Maintenance guide reference 5287...

Page 2: ...is compatible with its environment before its installation and also throughout its life The following preliminary precautions must be taken before working on any stationary device Mains voltage disco...

Page 3: ...iable to be changed without notice CONTENTS 1 RECEIPT 4 1 1 Identification 4 1 2 Storage 4 2 RECOMMENDATIONS 4 2 1 Commissioning 4 2 2 Mechanical installation 4 2 2 1 Brake with options 5 2 3 Electric...

Page 4: ...d check the winding insulation resistance phase earth resistance higher than 10 M Drain any condensation water 2 RECOMMENDATIONS 2 1 Commissioning The brake motor is designed to operate at the speeds...

Page 5: ...th a wear indicator while the brake is supplied with power the armature actuates a microswitch discrete fixed on the yoke If the brake lining is worn 0 6 mm the microswitch is actuated and informs the...

Page 6: ...e gland Cable gland type Standard cable gland polyamide Cable size Tightening torque Min cable mm Max cable mm Gland and body N m ISO 20a 5 12 2 ISO 20 7 14 2 ISO 25 9 18 3 FLS ES series Brass anchori...

Page 7: ...ect the rectifier cell when testing for current insulation or dielectric Sch ma de branchement Connection diagram FREIN BRAKE Coupure sur le continu obligatoire en levage ENLEVER LE STRAP Connection f...

Page 8: ...Power supply 230V AC Bobine coil 180V DC Bobine coil 180V DC 2 1 2 1 Bobine Coil Bobine Coil 2 1 Wiring diagram for Reduced response time option Built in power supply mandatory Frein brake 2 noir rou...

Page 9: ...og the cover grille and the housing fins Lubricate the bearings of the motors fitted with grease nipples Cleaning Precautions to be taken before carrying out any cleaning operation check that the brak...

Page 10: ...at least If the brake is not equipped with a release application indicator check the clearance periodically according to the rates and the energy to be dissipated on each braking operation see technic...

Page 11: ...0034 9 2005 A1 2007 60034 14 2004 A1 2007 60079 0 2012 A11 2013 60079 31 2014 60529 1991 A1 2000 IEC 60034 5 2000 A1 2006 60034 6 1991 60034 7 1992 A1 2000 60034 9 2003 A1 2007 60034 14 2003 A1 2007 6...

Page 12: ...Moteurs Leroy Somer Headquarter Boulevard Marcellin Leroy CS 10015 16915 ANGOUL ME Cedex 9 Limited company with capital of 65 800 512 RCS Angoul me 338 567 258 www leroy somer com...