b) the outlet used is the safety type
and that it includes a ground pin that
comes in contact with the pin on the plug
supplied with the device;
c) the outlet is connected to an
efficient ground system and that it is fed by
an electric plant protected by a residual
current circuit-breaker and high-sensitivity
magnetothermal switch (0.03A), all
coordinated to conform with the
prescriptions set forth by UNICEI EN
60204/1 Sept. 93 (see attached circuit
diagram). The switch must be installed on
the power supply line prior to and in the
vicinity of the machine;
d) the power supply cable section is
adequate for the length of that cable to avoid
an excessive voltage drop that might lead to
malfunctions.
Indicatively, a section of 2.5 mm
²
should be
used for distances of less than 30 m.
For greater distances, use cables with a
section that is greater than or equal to 4
mm
²
.
The hoist is controlled through a special
control panel which includes an up button
and a down button as shown in the
following diagram:
The hoist is controlled through a special
control panel which includes two SALITA-
DISCESA buttons as shown in the following
diagram:
For the three-phase asynchronuos
motor version, check that the load is in fact
lifted by pressing the corresponding
“SALITA”-“UP” button located on the
push-button panel.
If this does not occur, switch the two phase
wires in the power supply outlet.
A machine (lifting-lowering) test cycle must be
performed (under no load and then rated load
conditions), checking that the lifting limit
switch operates correctly and that the stand is
stable.
Check that the lifting limit switch operates
correctly at the beginning of each work shift.
The load braking system must be checked
every six months and, in any case, each time
that, during normal machine use, the load does
not stop immediately.