Nidec FGV-HXY Operation Manual Download Page 13

-12-

Press ZERO key to memorize the set value and come back from function mode to standard 
measuring mode.
In order to cancel the change of function mode, press POWER key, then turn the POWER off.

  5.8.Function mode-end

It's available to set PEAK signal mode.
Press the UNIT key to switch the PEAK signal mode.  Press PEAK key to go back to f01.

  5.7 PEAK signal mode: f07

Key operation

Display

PEAK

ZERO

MEM

UNIT

Press UNIT to cycle 

through settings

ZERO

Save current setting and return to the standard measuring mode.

PEAK

Save the change and then move to f01.

Not available PEAK signal

PEAK signal mode: +PEAK

PEAK signal mode: -PEAK

Key

Operation

POWER

Turn the POWER ON/OFF

ZERO

Tare (Peak reset at the PEAK Hold mode)

PEAK

Standard measuring mode / Plus peak hold mode / Minus peak hold mode

UNIT

Change the unit

MEM

Store the measuring data into memory

Key

Operation

How to operate

PEAK + UNIT

POWER

Tracking

ON / OFF

Turn POWER off. Press PEAK key and UNIT key simultaneously and hold, then 
press and release POWER key (release the PEAK key and UNIT key after the value 
appears in the display more than 1 second.)

ZERO + 

POWER

Function mode

Turn POWER off. Press ZERO key and hold, then press POWER key and release 
(release ZERO key after the value appears in the display more than 1 second).
Function mode;
UNIT: Change the setting content
PEAK: Switch the function
ZERO: Register the setting content

UNIT +

POWER

Reverse display

Turn POWER off. Press UNIT key and hold, then press POWER key and release 
(release the UNIT key after the value appears in the display more than 1 second.)

MEM +

POWER

Display memory data

Turn POWER off.  Press MEM key and hold, then press POWER key and release 
(release MEM key after the value appears in the display more than 1 second.)
Display memory data;
UNIT: Display the statistical data
PEAK: Memory data display end
ZERO: Delete one memory data 
Hold ZERO key to delete all data
MEM: Next memory data

PEAK +

POWER

Comparator 

memory mode setting

Turn POWER off. Press PEAK key and hold, then press POWER key and release.
In this setting;
UNIT : Change sign, number and memory mode
PEAK : Change the setting content
ZERO : Shift the digit
MEM  : Register the setting content

  6.Feature and Operation

  6.1.Overview of operation

1. Basic operation

2. Special operation

Summary of Contents for FGV-HXY

Page 1: ...e to the sensor may occur Do not modify disassemble or attempt to repair the unit Send to the factory for proper repair If upon delivery damage to the unit is detected do not operate the unit Notify t...

Page 2: ...ng Caution Warning Caution Safety Precaution Serious injury or possibly even death may result if the gauge is used wrongly A serious problem or issue may result if the gauge is used wrongly Take preca...

Page 3: ...ct load or excessive axial forces Bending direction Twisting direction Accuracy performance degrades overtime It is recommended the force gauge be checked for performance regularly The frequency of th...

Page 4: ...7 6 6 2 Storing data 18 6 6 2 1 Continuous memory mode 18 6 6 2 2 Single memory mode 18 6 6 2 3 Standard memory mode 18 6 7 Recalling memory data 19 6 7 1 Continuous memory mode 19 6 7 1 1 Measuring m...

Page 5: ...ith USB 6 9 USB communication 1000 data point memory 6 6 Memory Comparator shows pass or fail I O output of the result 6 5 Comparator Reverse the display of the measuring value and the unit 4 6 Revers...

Page 6: ...ng 7 POWER key Press the POWER and release to turn ON OFF It is used to reverse the display Tracking ON OFF It is used for comparator memory setting 8 MEM key Press the MEM key under the standard meas...

Page 7: ...of battery BAT is shown Even if turn the power off during the charge BAT will be displayed PEAK turns on when plus peak hold mode PEAK turns on when m i n u s p e a k h o l d mode Newton Depend on the...

Page 8: ...ours per 1 full charge 2 The nickel hydride battery is charged automatically when it is discharged during the usage of AC adapter If you charge the battery frequently its lifetime will be shortened Wh...

Page 9: ...Standard measuring mode Please release the PEAK key and UNIT key after the value appears in the display more than 1 second Tracking ON Tracking OFF Tracking OFF Tracking ON Turn power off then press...

Page 10: ...s 0001 Display update time f02 1 2 3 5 10 20 times second 3 Auto power off f03 10 10 minutes oFF not valid 10 RS 232C baud rate f04 2400 4800 9600 19200 bps 2400 Response Time f05 3 20 150 msec 3 Exte...

Page 11: ...easuring mode PEAK Save the change and then move to f04 5 3 Auto power off f03 If the gauge is on and there is no activity for 10 minutes the unit automatically powers off to conserve battery charge W...

Page 12: ...e 150msec Filter response time show 90 of step input Depend on the filter response sampling period and analog output update period is decided Input change of actual load Measuring value 90 response ti...

Page 13: ...key and UNIT key after the value appears in the display more than 1 second ZERO POWER Function mode Turn POWER off Press ZERO key and hold then press POWER key and release release ZERO key after the v...

Page 14: ...nder the plus peak hold mode or minus peak hold mode The plus peak value or minus peak value is cleared In plus peak hold or minus peak hold modes the tare cannot be performed even when pressing and r...

Page 15: ...ry mode setting MEM Set the memory mode single mode continuous mode standard mode Std When you set 0 at both HI limit and LOW limit comparater function does not work 6 5 3 Setting HI limit 1 Press the...

Page 16: ...n output signal of comparator LO limit 6 6 Memory There are 3 modes at memory mode as follows Continuous memory Allows the recording of up to 1000 data points The recording starts when you push MEM an...

Page 17: ...N MIN Continuous memory mode Ex1 Ex2 Ex3 MAX MAX MIN 0 MIN 0 MAX MAX MAX MIN Start memory Start memory Start memory Finish memory Finish memory Finish memory 0 0 0 MIN 0 MAX 0 Average value AVE Averag...

Page 18: ...it 0 Comparator LO limit setting LO Set comparator LO limit 0 Memory mode setting MEM Set memory mode Single mode Continuous mode Standard mode Std When you set 0 at both HI limit and LO limit compara...

Page 19: ...umber arrives at 1000 6 6 2 2 Single memory mode 1 During the standard measuring mode press MEM key M turns on at the unit display and one data is recorded 2 If 100 data points are recorded FULL appea...

Page 20: ...orded measurement value of that block 2 Press MEM to review the previous data block recorded 3 Press UNIT to cycle through the available recorded statistics In Continuous mode the available statistics...

Page 21: ...egative maximum value positive minimum value negative minimum value positive peak value negative peak value average value standard deviation 3 Press MEM to exit to the recorded measurement values 4 Pr...

Page 22: ...s and release POWER Release MEM when you see Slg on the display The unit will alternate between showing the data block number and the recorded measurement value of that block 2 Press MEM to review the...

Page 23: ...ing RS232C communication Key operation Display Turn power off PEAK ZERO MEM UNIT 1 Hold down MEM key 2 Press POWER key PEAK ZERO MEM UNIT Release POWER key only MEM Return to memory data display PEAK...

Page 24: ...a greater detail in the next section 4 Press PEAK to output the recorded memory via RS 232C Refer to section 7 regarding RS232C communications Key operation Display Turn power off PEAK ZERO MEM UNIT...

Page 25: ...itive minimum value negative minimum value positive peak value and negative peak value 3 Press MEM to exit to the recorded measurement values 4 Press PEAK key to output the recorded memory via RS 232C...

Page 26: ...USB 6 9 2 Download ToriemonUSB If you connect the force gauge to a PC with the USB cable you can download data to the PC from the force gauge of the current values being measured or from data that is...

Page 27: ...put can be set by external output setting f06 of function mode 7 2 RS 232C Output You can operate this equipment from your PC if connecting it by using optional cable for RS 232C Cannot use USB commun...

Page 28: ...t and 4 digit number BBcr Request for continuous transmission of measuring data 10 times second BBcr NAoooooocr BB1cr Request for continuous transmission of measuring data 20 times second BB1cr NAoooo...

Page 29: ...rnal output setting f06 function mode Maximum allowance voltage DC 30V current 5mA Please connect the power and load to avoid going over maximum allowance Overload output When the overload condition i...

Page 30: ...limit output 8 ZERO signal input Input signal 9 HOLD signal input 10 PEAK signal input 11 Common for comparator output 12 GND The device printer provided for Mitutoyo Digimatic Please purchase the opt...

Page 31: ...gnal input 9pin ZERO signal input 10pin GND 12pin Signal is ON DC 3 3V 0 5mA 2 HOLD signal input HOLD signal is ON when HOLD signal input pin 9 pin and GND 12 pin is changed from OPEN to CLOSE The dis...

Page 32: ...it Questions Explanation Reference How long does rechargeable battery Nickel hydride battery last Enable to use 500 times or more by complete electric discharge It depends on the status of use Please...

Page 33: ...CHECKED UNITS SCALE TITLE Toshi MO YS mm 1 1 MODEL ORIGINAL DRAWING NO DRAWING NO BGBM068 FGC H FGV H FGN H FGE H High Load Force Gauge Attachment Drawing M10 EJ350280 DATE 04 24 2017 Itasca IL 60143...

Page 34: ...33...

Reviews: