background image

4

Fig. 4-3(a)

Fig. 4-3(b) 

4.4 Delete All
All data points can be cleared from memory under the Delete all 
sub-menu (Fig. 4-4). A confirm window will appear asking you to 
confirm. See Browse for details on deleting individual points one 
at a time.

Fig. 4-4

5. SYSTEM

Under the System menu, the Display, Auto Power, Backlight, Key 
Sound, Date/Time, Calibration and Default sub menus are pres-
ent.

Fig. 5

5.1 Display
There are two display modes: Obverse and Reverse (Fig. 5-1(a)). 
Obverse will allow the display to be up-right with the keypad un-
derneath, while Reverse will allow the display to be up-right with 
the keypad above. Fig. 5-1(b)

                                 

                         Fig. 5-1(b)
5.2 Auto Power
The FG-3000R has an automatic power off function. With Auto 
Power on, if there is no operation performed within five minutes it 
will power off automatically. (Fig. 5-2) 

Fig. 5-2

5.3 Backlight
The backlight can be set to turn on or off. See Fig.5-3. Choosing 
the backlight to be off will reduce the consumption of the battery.

Fig. 5-3

5.4 Key Sound
The Key Sound can be turned on or off as shown in Fig. 5-4.

Fig. 5-4

5.5 Date/time
Date and time can be adjusted under this menu. Press ZERO to 
adjust the number and press MODE to move to the next digit. Fig. 
5-5

Fig. 5-5

Fig. 5-1(a)

Obverse

Reverse

Summary of Contents for FG-3000R-S

Page 1: ...s Do not use damaged clamp Measure in line tension and compression forces only DO NOT attempt to measure forces at an angle to the measuring shaft damage to load cell and or shaft may result Do not attempt to repair or alter this instrument Warranty will be voided and damage to the unit may result Use and store within the stated temperature and humidity ranges or damage and failure may result When...

Page 2: ...PARATION 2 1 Confirm the model This series force gauge has 5 ranges available each model corre sponding to the capacity and resolution shown on the last page of this manual Select the appropriate model you need before use 3 SETUP 3 1 Measurement The Measurement menu contains the Unit of measure and Mea surement Mode sub menus as shown in Fig 3 1 Fig 3 1 3 2 Select Units The measuring units can be ...

Page 3: ...s the peak value shown on the display 4 1 Memory Fig 4 1 Memory menu contains three submenus Browse Print Delete all as shown in Fig 4 1 You can browse stored data or print all the data via the FG PRINTER mini printer sold separately You may also delete all the records in the Delete all sub menu 4 2 Browse In the Browse sub menu The data in memory can be reviewed in the order saved which is oldest...

Page 4: ... keypad un derneath while Reverse will allow the display to be up right with the keypad above Fig 5 1 b Fig 5 1 b 5 2 Auto Power The FG 3000R has an automatic power off function With Auto Power on if there is no operation performed within five minutes it will power off automatically Fig 5 2 Fig 5 2 5 3 Backlight The backlight can be set to turn on or off See Fig 5 3 Choosing the backlight to be of...

Page 5: ...after a period of usage It is recommended to send the force gauge to a specialized test ing organization for calibration If you have standard force weights or other standard load and a test stand you may utilize this function and procedure to calbrate the sensor Fig 5 6 a 1 Mount the force gauge 2 Use the tare by use of the ZERO key 3 Enter Calibration sub menu as in Fig 5 6 a The calibration inte...

Page 6: ... bits Stop bit 1bit Parity None Baud rate 38400 Fig 8 2 8 2 Setpoint Output Two NPN open collector setpoint outputs are available The internal circuit of the setpoint output is shown as Fig 8 2 Pin7 with Pin6 will be connected when an overload alarm occurs In Preset Mode Pin7 to Pin6 is connected when the measured value exceeds the upper limit Pin4 to Pin6 is connected when the measured value pass...

Page 7: ...ty 1000 1 100 220 Resolution 1 0 001 0 01 0 01 FG 3000R 5 Capacity 5000 5 500 1100 Resolution 1 0 001 0 1 1 FG 3000R 10 Capacity 10 1000 2250 Resolution 0 01 1 1 FG 3000R 20 Capacity 20 2000 4500 Resolution 0 01 1 1 FG 3000R 50 Capacity 50 0 5000 11 Resolution 0 01 1 0 01 ...

Page 8: ...SEALS USA Inc Instruments Division Tel 630 924 7138 Email support seals usa com ...