background image

AV44 Solid Shaft Incremental Encoder

4

Rev: 003

All Connector Options except “B” and “3” have Standard Phasing, A Leads B for CW rotation, viewed from load side of motor.

Note for Connector Options B and 3 with Reverse Phasing, the Phasing is inverted via Configuration; the Wiring and Pinout is the same as for Standard 
Phasing (Connector option A or 2 respectively). For Connector Option with Reverse Phasing, B Leads A for CW rotation, viewed from load side of motor.

CW

Front of Encoder

Standard Phasing: A Leads B for CW Rotation (viewed from front of encoder) 

Reverse Phasing: B Leads A for CW Rotation (viewed from front of encoder) 

WIRING DIAGRAM / PINOUT

Connector

Option “W” 

(Cable)

Option “A”, “B” 

(10-Pin MS)

Option “2”, “3” 

(M23 12-Pin)

Option “T” 

 (M12 8-Pin)

Option “U” 

 (M12 8-Pin)

Option “Y” 

 (Terminal Strip)

Ref Signal

Encoder Wiring

Green

A

5

3

1

8

A

Yellow

H

6

4

3

7

/A

Blue

B

8

5

4

6

B

Gray

I

1

6

5

5

/B

Orange

C

3

7

6

3

Z

White

J

4

8

8

4

/Z

Violet

N/C

11

N/C

N/C

9

/ALM”

Red

D

12

2

2

1

+Vin

Black

F

10

1

7

2

GND

* Remote alarm output for mod 068 code only

Summary of Contents for Avtron AV44

Page 1: ...ckage the AV44 can maintain itself and provide an alarm if there is a problem before the problem causes unscheduled downtime ADAPTIVE ELECTRONICS A perfect duty cycle consists of a waveform whose high...

Page 2: ...et head cap screws supplied 9 Align bolt holes of encoder flange and the mounting flange flowerpot thread in socket head cap screws Torque to 5 ft lb 7 N m 10 Tighten fasteners on encoder side of coup...

Page 3: ...r adjustment limit This output occurs before an actual failure allowing steps to be taken to replace the unit before it causes unscheduled downtime If the alarm output and or LED indicate a fault RED...

Page 4: ...for CW rotation viewed from load side of motor CW Front of Encoder Standard Phasing A Leads B for CW Rotation viewed from front of encoder Reverse Phasing B Leads A for CW Rotation viewed from front...

Page 5: ...4096 A2 8192 K1 10000 Contact Factory for Additional PPRs XX None 000 No Special Mods 9XX Custom Cable Length 068 Remote Alarm Output 070 Expanded Temp Range 40 100C 077 4500 6000 RPM Custom Cable Len...

Page 6: ...N Speed Weight 6000 RPM Max 2 5 lbs 635 g approx Temperature Certifications 30 to 85 C std optional 40 to 100 C CE UL B37178 cable offers excellent noise performance minimized power supply loss and ul...

Page 7: ...subject to change without notice Nidec Industrial Solutions standard warranty applies All dimensions are in mm inch OUTLINE DRAWINGS 11mm SHAFT with 4mm KEY B10 EUROFLANGE CABLE GLAND 5 16 SHAFT WITH...