AV44 Solid Shaft Incremental Encoder
4
Rev: 003
All Connector Options except “B” and “3” have Standard Phasing, A Leads B for CW rotation, viewed from load side of motor.
Note for Connector Options B and 3 with Reverse Phasing, the Phasing is inverted via Configuration; the Wiring and Pinout is the same as for Standard
Phasing (Connector option A or 2 respectively). For Connector Option with Reverse Phasing, B Leads A for CW rotation, viewed from load side of motor.
CW
Front of Encoder
Standard Phasing: A Leads B for CW Rotation (viewed from front of encoder)
Reverse Phasing: B Leads A for CW Rotation (viewed from front of encoder)
WIRING DIAGRAM / PINOUT
Connector
Option “W”
(Cable)
Option “A”, “B”
(10-Pin MS)
Option “2”, “3”
(M23 12-Pin)
Option “T”
(M12 8-Pin)
Option “U”
(M12 8-Pin)
Option “Y”
(Terminal Strip)
Ref Signal
Encoder Wiring
Green
A
5
3
1
8
A
Yellow
H
6
4
3
7
/A
Blue
B
8
5
4
6
B
Gray
I
1
6
5
5
/B
Orange
C
3
7
6
3
Z
White
J
4
8
8
4
/Z
Violet
N/C
11
N/C
N/C
9
/ALM”
Red
D
12
2
2
1
+Vin
Black
F
10
1
7
2
GND
* Remote alarm output for mod 068 code only