17
High Security Mode
Memory 88
(Factory Default: Normal Mode)
The high security mode memory is used to select the mode
that the PAC1 operates in. The value programmed into
memory 88 selects either Normal Mode, Any Two User
Codes, Code 000 or 001 and any other user code or
Sequential Memory User Codes. For a description of each
of these operating modes refer to the
High Security Mode
section on page 6.
To select Normal Mode (High Security Mode Disabled)…
*
8
8
0
E
To select Any Two User Codes mode…
*
8
8
1
E
To select Code 000 or 001 and any other user code mode…
*
8
8
2
E
To select Sequential Memory User Codes mode…
*
8
8
3
E
IMPORTANT NOTE:
When the PAC1 is set up to use any
of the high security modes above (not Normal Mode) the
ELC relay will only operate in
Momentary (timed) Mode
even if the codes are programmed as Toggle codes.
High Security Mode Timing
Memory 89
(Factory Default: 60 seconds)
If the PAC1 is set up to operate in any of the High Security
Modes above, then the two codes must be entered within
the time specified in memory 88. This time may be set
between 1 and 255 seconds.
To set the time allowed between two codes…
*
8
9
“the time in seconds”
E