15
ELC Relay Type
Memory 82
(Factory Default: Normally Open)
The electronic latch control (ELC) relay can be set to
operate as either Normally Open (N.O.) for fail secure or
Normally Closed (N.C.) for fail safe.
To set the ELC relay type to normally open…
*
8
2
0
E
To set the ELC relay type to normally closed…
*
8
2
1
E
ELC Operating Time
Memory 83
(Factory Default: 10 seconds)
The electronic latch control (ELC) relay can be set to
operate for 1 second to 255 seconds in 1 second
increments.
To change the ELC operate time…
*
8
3
“the time in seconds”
E
Door Input Enable
Memory 84
(Factory Default: Disabled)
If the “Door Open Too Long” and “Door Forced Open”
functions are required then the input from the door switch
must be enabled. Note: enable only if your door has a reed
switch or the latch is monitored.
To disable the door input…
*
8
4
0
E
To enable the door input…
*
8
4
1
E