13
All other values = Keypad will only make beeps, warble, etc. for DTA
chars received after pressing the final
#
key.
Note:
This memory only has an effect when the keypad is in Presco
mode (either through the Pink wire or Memory 005 = 101), in Wiegand
mode all received chars on the DTA line are ignored.
Setting the options via the VR keypad
To set any of the above options the keypad first needs to be
placed into program mode, this is done by the following method:
1. Remove power from the VR keypad.
2. Hold down
the
3
,
6
&
9
keys.
3. Reapply power whilst continuing to hold down the keys.
4. Once the red & green LEDs start to flash alternatively to
indicate you are in program mode release the keys.
5. The keypad will remain in program for 5 mins from the last
attempted programming sequence.
Programming a memory
*
<3 digit memory number> <1 to 3 digit memory value>
#
.
Reset all memories to factory defaults
*987654#
whilst in program mode.
Exit Program Mode
*999#
or wait 5 minutes after last programming attempt.