Nico Technology 1208L User Manual Download Page 2

 1208L Analog Input Module 

User’s Manual

Rev.1.0 

This Manual 

This manual provides any required information for installation, configuration 

and operation of the Nico Technology Ltd. 1208L Analog Input Module. 

It exclusively treats the handling of this device. It neither describes the 

LonWorks technology by Echelon nor the LonMark profile implemented in 

detail. More specific information concerning these subjects can be found in the 

documentation of Echelon (

www.echelon.com

) and the LonMark 

Interoperability Association (

www.lonmark.org

). 

The first part of this manual provides a survey about the device and its 

installation in chapters 1 to 3. The 2

nd

 part describes the implemented 

application for lighting control and its configuration possibilities. Chapter 4 

contains a description of the firmware interface while chapter 5 describes the 

implemented LonMark Objects in detail providing an outlook of the individual 

objects, their tasks and their relevant configuration parameters. 

Chapter 6 explains the basics required to connect the objects to each other. 

This manual is relevant for all variants of the Nico Technology Ltd. 1208L 

Analog Input Module where applications for building automation control are 

implemented. 

This documentation is subject to modification at any time without prior advice. Nico does not take over any 

responsibility for mistakes or inaccuracies in this documentation and eventually occurring consequences. 

In any case Nico as well as its representatives and staff are not reliable for eventual defaults, damages caused 

indirectly or during use, occurring due to the use or non-usability of the software or the accompanying documentation. 

Nico is a registered trademark of Nico Technology Ltd. 

Echelon, LON, LonMark, LonWorks and Neuron are registered trademarks of Echelon Corporation. Other name may 

be registered trade marks of the respective companies. 

Summary of Contents for 1208L

Page 1: ...ual 1 Rev 1 0 1208L Analog Input Module Revision 1 0 Nico Technology Ltd 6F No 93 Xinhu 1st Rd Neihu Dist Taipei City 114 Taiwan Phone Fax Product Info 886 2 2790 6308 886 2 2790 6603 sales nico tech...

Page 2: ...e implemented LonMark Objects in detail providing an outlook of the individual objects their tasks and their relevant configuration parameters Chapter 6 explains the basics required to connect the obj...

Page 3: ...Hardware Survey 8 4 2 Operation and Display Elements 8 4 3 Connection Pin Assignment 9 4 4 Wiring Diagram 11 4 5 EMC 12 4 6 Technical Specifications 13 4 7 Dimensions 13 5 Application Software for Bu...

Page 4: ...1208L Analog Input Module No Description 1 Input channels for 0 10VDC or 4 20mA 2 3 24VDC Input power 4 T1 T2 for Connect to LonWorks network 5 24VDC Input power 6 T1 T2 for Connect to LonWorks networ...

Page 5: ...elevant national standards The connection to the supply voltage must be performed in accordance with VDE 0100 and VDE 0160 or the relevant national standards Installation should perform by qualified a...

Page 6: ...ual 6 Rev 1 0 3 2 Mounting 3 3 Connections The 1208L Analog Input Module has to be connected to a 24VDC power supply and to the LonWorks network According to the respective application peripheral equi...

Page 7: ...nnections are through connected in order to achieve easy wiring LonWorks Network The connection to the LonWorks network is made by means of twisted pair cables The connection shield has to be connecte...

Page 8: ...ammable in Neuron C As a flash module is used the application can be load via the LonWorks network making the 1208L an I O controller e g for detail info please contact Thomas nico tech com 4 1 Hardwa...

Page 9: ...ctions the 1 marking cf Figure 1 1 On previously page In each clamp block pin 1 is situated on the left For further wiring information see figure 3 2 LonWorks Network Connection The double core bus li...

Page 10: ...ctor pin assignment output circuit Power Supply The 1208L Analog Input Module has to be connected via connector 2 3 5 7 to 24VDC main voltage Also see figure 1 1 Figure 3 3 Connector pin for Power Sup...

Page 11: ...1208L Analog Input Module User s Manual 11 Rev 1 0 4 4 Wiring Diagram Figure 3 5 Connecting to 1208L Figure 3 6 Connecting to other one of 1208L or LonWorks device...

Page 12: ...cording to the regulation 89 336 EEC for electron magnetic compatibility modified by 92 31 EEC Concerning the emission it fulfills classification B living area according to EN 55022A B EN 55011 A B an...

Page 13: ...rew clamp 2 5mm for output channels 3 0mm for DC power supply and LonWorks network communication port Operation 0 50 Temperature Storage 20 70 Admitted relative humidity 5 93 non condensing Dimensions...

Page 14: ...1 NV Type Translator Object Table 4 1 Referring document about LonMark profiles 5 1 System Scope The 1208L Analog Input Module is equipped with eight channels for Analog Output The analog outputs of t...

Page 15: ...208L The XIF file is necessary for integration with LonMaker for Windows or any other LonWorks network management tool 6 System Objects This chapter describes the LonMark objects implemented in the 12...

Page 16: ...CPTlocation 17 Additional free comment 6 3 Nico Tech NV Type Translator Object Network Variables NV Name NV Type Comment nvInput SNVT_lev_percent Changeable Type translator of Nv input value nvOutput...

Page 17: ...sTblY 29 Used in conjunction with Translation table Y to scale and linearity a value SCPTlocation 17 Location Label 7 Configure 1208L between 0 10VDC and 4 20mA This chapter describes the how to confi...

Page 18: ...1208L Analog Input Module User s Manual 18 Rev 1 0 Figure 7 2 connect 1208L to different type of sensor...

Reviews: