7
466mm
410mm
Step 1:
Loosen all 4 x screws but do not remove.
Step 3:
Tighten all 4 x screws again.
Step 2:
Rotate the clutch assembly 180°,
so that the hand-chain hangs
vertically off the bottom of the
operator.
Mounting orientation options and required clearance.
Ensuring the hand-chain always hangs vertically off the bottom of the operator.
Infront of drum.
Adjacent to drum.
Where to position the equipment
Liquid ingress:
The Nice iDoor RS products are not designed for external use. They are not water tight as there are sensitive electronic and electrical circuits that
require uninhibited airflow to remain cool and dry.
When deciding on an installation position, be aware of water ingress points around and near the desired mounting position of the equipment. If
there is any possibility of water ingress, either via vapour or directly, the equipment should not be installed. Failure to adhere to this will result in an
electrocution and or fire risk.
Physical protection:
Always install the equipment where it will be clear of moving objects. This is especially true of the cabling that can be damaged if snagged.