sions) the command, its own identification code and the “enabling code” received. At this point, the receiver
will recognise the enabling code of the old transmitter and automatically memorise the identification code of
the new transmitter.
• The undesired memorisation of transmitters through the “enabling code” can be prevented by blocking the
receiver’s function through Procedure 7 (Paragraph 3.8). Alternatively, the receiver can be blocked also with the
O-Box programmer, by intervening on the receiver or on the transmitters already memorised.
3.5 - Memorising (in the receiver) the control unit Series/Address, for the BusT4 network
The OXIBD (OXIBD/A) receiver can interact with a single control unit through the “BusT4” network. If the system
contains multiple control units connected to each other via “BusT4”, before carrying out the following procedure
the cable of the “BusT4” network must be disconnected from the control unit on which the Series/Address will
be memorised.
PROCEDURE 4 - Memorising (in the receiver) the control unit Series/Address, for the BusT4
network
01.
Disconnect the power supply and wait 5 seconds.
OFF
5
s