Generalities:
The automatic operation of the motor by means of the commands received by the cli-
mate sensors does not block the manual commands sent by the user of the shutter.
– “Rain present” and “wind over threshold” conditions inhibit the operation of the sun
sensor.
– The manual command “Sun-ON” enables (“Sun-OFF” disables) only the operation
of the Sun sensor.
– The manual commands Raise, Stop, Lower and Partial Opening sent by the user
to the motor do not deactivate the operation of the Sun Wind or Rain sensors un-
less the
command completely closes the shutter.
– When the shutter is completely closed, no climate sensor is able to open it in au-
tomatic mode.
“
0
”
“
1
”
5
0
10
15
20
25
35
40
30
45
Klux
light
intensity
automatic
operation
manual
operation
momentary drops
in light, within the
hysteresis values
drops in light, within
the under-threshold
values
set threshold
value: e.g.
30Klux
over-threshold
hysteresis
under-threshold
active manual commands
system deactivated
after 2 minutes
after 15 minutes
system active
hysteresis threshold:
po-
sitioned automatically at half
the set threshold value
sunrise
daytime
dusk
night-time
system deactivated
6
“
0
”
“
1
”
presence / absence
of rain
automatic
operation
manual
operation
active manual commands
system deactivated
system deactivated
after 3 seconds
after 15 minutes
sensor dry
system active
7