background image

1

3

5

6

4

5

2

1

2

3

4

7

Ø5 mm

Ø5 mm

9

1

2

Summary of Contents for MNCUC

Page 1: ...Nice MNCUT MNCUTC MNCUC EN Instructions and warnings for installation and use MyNice control unit...

Page 2: ......

Page 3: ...rdy Do not place the system s components close to sources of strong heat as this may damage them Each sensor has its own operating principle check the suitability of the intended positioning against t...

Page 4: ...aining from 1 to 99 detectors Depending on the type and size of the system there are 3 control unit models to choose from MNCUT MyNice control unit 99 zones in 6 areas dual band two way radio with 7 c...

Page 5: ...h screen good visibility can be obtained even at 35 Technical characteristics Current draw Table 1 Code MNCUT MNCUTC MNCUC Power supply 110 V 240 V 110 V 240 V 110 V 240 V Surveillance 18 18 18 Radio...

Page 6: ...l unit after carefully considering the following aspects the control unit without the display must be positioned at least 1 metre above the floor to favour the Wi Fi communication Place the versions w...

Page 7: ...in the outdoor area subsequently activating the siren at full power and making phone calls in case of attempted break ins involving the inner areas Example of block subdivision Fig 3 Area 1 Garden de...

Page 8: ...5 The electrical connections 6 The installation of the control unit see Installing the control unit Since the system components communicate via radio it is advisable to first configure the system on a...

Page 9: ...1 3 5 6 4 5 2 1 2 3 4 7 5 mm 5 mm 9 1 2...

Page 10: ...reply with 1 beep Interruption of alarm calls Enter the indicated codes and wait for the reply the control unit will reply with the recorded voice messages or if none are recorded with acoustic signal...

Page 11: ...rom any telephone number by entering after the reply signal the User PIN code followed by If the voice messages have been recorded correctly the control unit will reply with the following voice messag...

Page 12: ...y detectors sirens equipped with the appropriate input The fault input if used triggers the ANOMALY signal and the rela tive warning messages All unused inputs may be left without any connection they...

Page 13: ...alarm inputs alarm inputs tamper inputs only with inputs used in NC mode Warning Not conforming to EN 50131 close on GND R22k balanced fault input EN 50131 close on GND 12 V for supplementary sirens g...

Page 14: ...tdoors with voice messages and LED flashing light MNSC Wired siren for outdoors with voice messages and LED flashing light for MNCUTC and MNCUC only MNSI Two way dual band radio siren for indoors with...

Page 15: ...stance or physical obstacles lying in between the radio range between the control unit and certain devices must be extended The repeater must be placed at an equal distance from the control unit and f...

Page 16: ...ge 2 of the sirens Specific parameters of MNMC and MNGB magnetic contact detectors Door open signal normally enabled EN 50131 but can be disa bled If active it signals any open doors windows when the...

Page 17: ...It is obtained by adding 1 to the last digit of the PIN for example PIN 11111 duress function activation code 11112 or PIN 11119 duress function activation code 11110 In case of error calls can be dis...

Page 18: ...aid panic and aggression aid GSM calls periodic messages Internet connection Contact ID digital protocols Other communication parameters To activate and manage reception of alerts via e mail Email To...

Page 19: ...hat the smartphone is connected to the Wi Fi or is nonetheless enabled to exchange data if the control unit is connected in Access Point mode connect the smartphone to the WLAN of the control unit Acc...

Page 20: ...IS0602A01EN_22 12 2017 www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com...