background image

Applicable regulations, general warnings and precautions

This manual contains important 

information regarding installation 

safety; it is important to read all the 

instructions prior to installing the 

product. Keep this manual for future 

use. Further information is available at: 

www.niceforyou.com

It is forbidden to use the products for 

purposes other than those indicated 

in these instructions.

Do not effect modifications to any 

part of the product other than those 

described in this manual: they may 

cause malfunctions. Nice S.p.A. 

declines all liability for damage caused 

by modified products.

When installing and using the product, 

make sure that any foreign bodies 

(solid or liquid) do not enter the 

devices when they are open.

Manufacturer’s responsibility:

 Nice 

S.p.A. declines all liability for faults 

resulting from incorrect installation, 

lack of maintenance and incorrect 

use. Furthermore, Nice S.p.A. shall 

not be held liable for the product’s 

incomplete operation.

Warranty (summary of terms and 

conditions):

 Nice S.p.A. guarantees 

its products against concealed faults 

for a period of 3 years from the date 

of manufacture. The warranty applies 

to direct purchasers of the Nice 

S.p.A. product; no warranty applies 

to the end user, who must contact 

their installer or dealer in case of 

malfunctions.

Warranty exclusions:

 the following 

are excluded from the warranty: 

aesthetic components, parts 

subject to normal wear and tear and 

consumables, such as cells, batteries 

and accumulators.

The installation manual is exclusively 

intended for technical personnel 

qualified to carry out the installation.

Considering the hazards that may 

arise during the system’s installation 

and operation, for reasons of safety 

installation must be carried out in 

strict compliance with the current 

legislation, standards and regulations.

Disconnect all power supply circuits 

before accessing the product’s 

internal terminals.

If any automatic switches or fuses trip, 

identify and eliminate the cause before 

resetting them.

Check that all the materials are in 

good working order and suited to the 

intended applications.

Check that the radio frequencies used 

by the product are locally approved 

for use in alarm systems.

Before installing the equipment, check 

the products’ environmental class (see 

Technical specifications - Table 1).

Check that the radio range of the 

devices exceeds the physical distance 

between the various products (see 

Technical specifications - Table 1).

Check that the various devices 

(sensors, control unit, etc.) are 

mounted in zones protected against 

impacts and that the mounting 

surfaces are sufficiently sturdy.

Do not place the system’s 

components close to sources of 

strong heat as this may damage them.

Each sensor has its own operating 

principle: check the suitability of the 

intended positioning against the 

warnings given in the respective 

instruction manuals.

The Nice S.p.A. Technical Assistance 

Service, reserved for professionals, is 

at your disposal during the following 

periods:

Monday to Friday from 8:30 to 18:30 

and Saturday from 09:00 to 12:00.

Tel. +39 0422 1838383

E-mail: [email protected]

The control unit and the 

programmable parameters of the 

individual devices are set to average 

default values conforming to the EN 

50131 standard. In certain cases 

modifications are signalled that imply 

breaches to the EN 50131 standard: 

the responsibility for any decisions in 

this regard bears on the installer and/

or user.

The EN 50131 standard defines the 

Grade 2 minimum autonomy for 

power shortage at 12 hours: it must 

be guaranteed by correct installation 

(see Current draw - Table 2).

All devices of this alarm system 

constitute an integral part of the 

installation and must be disposed 

of together with the latter. Similarly 

to the installation operations, once 

the products reach the end of their 

useful life, they must be dismantled 

by qualified personnel. These 

products are made of various types 

of materials, some of which can 

be recycled while others must be 

scrapped. Find out about recycling 

and disposal systems in use in your 

area for this category of products.

Warning!

 Some parts of the products 

may contain pollutants or hazardous 

substances which, if released into 

the environment, may cause serious 

damage to the environment or human 

health.

Warning!

 It is forbidden to dispose 

of these products together with 

household waste. Separate the waste 

into disposal categories according 

to the methods established by 

regulations applicable in your area, 

or return the products to the retailer 

when purchasing a new equivalent 

version.

Disposal of cells and batteries

 

The cells and batteries used in this 

alarm system, even when exhausted, 

contain polluting substances and 

therefore must not be disposed of 

as household waste. They must be 

disposed of according to separate 

waste collection methods as 

envisaged by the local regulations.

Disposal of the packaging

 

The packaging materials must be 

disposed of in compliance with the 

local regulations.

General warnings

Supplementary warnings for mains powered devices

Installation warnings

Technical assistance

EN 50131 standard

Disposal of the product

Hereby, NICE S.p.A., declares that the 

radio equipment type

MNCUT

MNCUTC

MNCUC

is in compliance with Directive 

2014/53/EU.

The full text of the EU declaration of 

conformity is available at the following 

internet address:

http://www.niceforyou.com/en/

support

EC Declaration of 

Conformity

Summary of Contents for MNCUC

Page 1: ...Nice MNCUT MNCUTC MNCUC EN Instructions and warnings for installation and use MyNice control unit...

Page 2: ......

Page 3: ...rdy Do not place the system s components close to sources of strong heat as this may damage them Each sensor has its own operating principle check the suitability of the intended positioning against t...

Page 4: ...aining from 1 to 99 detectors Depending on the type and size of the system there are 3 control unit models to choose from MNCUT MyNice control unit 99 zones in 6 areas dual band two way radio with 7 c...

Page 5: ...h screen good visibility can be obtained even at 35 Technical characteristics Current draw Table 1 Code MNCUT MNCUTC MNCUC Power supply 110 V 240 V 110 V 240 V 110 V 240 V Surveillance 18 18 18 Radio...

Page 6: ...l unit after carefully considering the following aspects the control unit without the display must be positioned at least 1 metre above the floor to favour the Wi Fi communication Place the versions w...

Page 7: ...in the outdoor area subsequently activating the siren at full power and making phone calls in case of attempted break ins involving the inner areas Example of block subdivision Fig 3 Area 1 Garden de...

Page 8: ...5 The electrical connections 6 The installation of the control unit see Installing the control unit Since the system components communicate via radio it is advisable to first configure the system on a...

Page 9: ...1 3 5 6 4 5 2 1 2 3 4 7 5 mm 5 mm 9 1 2...

Page 10: ...reply with 1 beep Interruption of alarm calls Enter the indicated codes and wait for the reply the control unit will reply with the recorded voice messages or if none are recorded with acoustic signal...

Page 11: ...rom any telephone number by entering after the reply signal the User PIN code followed by If the voice messages have been recorded correctly the control unit will reply with the following voice messag...

Page 12: ...y detectors sirens equipped with the appropriate input The fault input if used triggers the ANOMALY signal and the rela tive warning messages All unused inputs may be left without any connection they...

Page 13: ...alarm inputs alarm inputs tamper inputs only with inputs used in NC mode Warning Not conforming to EN 50131 close on GND R22k balanced fault input EN 50131 close on GND 12 V for supplementary sirens g...

Page 14: ...tdoors with voice messages and LED flashing light MNSC Wired siren for outdoors with voice messages and LED flashing light for MNCUTC and MNCUC only MNSI Two way dual band radio siren for indoors with...

Page 15: ...stance or physical obstacles lying in between the radio range between the control unit and certain devices must be extended The repeater must be placed at an equal distance from the control unit and f...

Page 16: ...ge 2 of the sirens Specific parameters of MNMC and MNGB magnetic contact detectors Door open signal normally enabled EN 50131 but can be disa bled If active it signals any open doors windows when the...

Page 17: ...It is obtained by adding 1 to the last digit of the PIN for example PIN 11111 duress function activation code 11112 or PIN 11119 duress function activation code 11110 In case of error calls can be dis...

Page 18: ...aid panic and aggression aid GSM calls periodic messages Internet connection Contact ID digital protocols Other communication parameters To activate and manage reception of alerts via e mail Email To...

Page 19: ...hat the smartphone is connected to the Wi Fi or is nonetheless enabled to exchange data if the control unit is connected in Access Point mode connect the smartphone to the WLAN of the control unit Acc...

Page 20: ...IS0602A01EN_22 12 2017 www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com...

Reviews: