13
GB
STOP
Photo
Photo
1
Step
by
Step
AUX
STOP
PP
Auto
Cond.
Pre-
flashing
Close
after
photo
Leaf
delay
Normal
operation
OK Led
slow flashing
Level one
OK Led
permanently on
Level two
OK Led
rapid flashing
5
10
20
seconds
40
80
PAUSE TIME
type 1
p.o.
type 2
p.o.
only
opening
only
closing
Photo 2
AUXILIARY IMPUT (*)
2
4
6
seconds
8
10
PRE-FLASHING TIME
1
All Leds off
➡
current sensitivity disabled
2
3
degree
4
5
CURRENT SENSITIVITY
2
4
6
seconds
8
10
MOTOR 1 DELAY
P1+P2
for 3 secs
P1
for 3 secs
(no save)
P1+P2
for 3 secs
(save)
P2
for 3 secs
P1
P1
P2
P1
P2
P1
P2
P1
P2
P1
P2
P1
P2
1
2
P1
P2
on
off
4.2.5) Programming diagram
The following figure shows the complete programming diagram of
the functions and relative parameters.
This figure also shows the functions and parameters as they were
initially or following total memory deletion.
(*)
type 1 p.o.
type 1 partial open,
only motor 2 moves [N.O.]
type 2 p.o.
type 2 partial open
both motors move for 1/2 the work time [N.O.]
only open
open
➔
sto
➔
open
➔
stop … … [N.O.]
only close
close
➔
stop
➔
close
➔
stop … … [N.O.]
photo 2
used as photo 2 [n.c.]