background image

Page 7

Using the Keypad

Normal operation:

Alarm Monitoring Function:

Bypass Function:

To activate Relay1/Lock output, simply type in a valid code for that relay or press and release the free exit push button if one
has been installed:

 

-The relay will activate in the manner setup by the installer.

 

-The green LED indicator will activate as per the relay.

To activate Relay2/Aux output, simply type in the valid code for that relay or press and release the free exit push button if this 
function has been configured and installed:

 

-The relay will activate in the manner setup by the installer.

 

-The yellow LED will activate as per the relay.

If the alarm monitoring has been set up by the installer, and an alarm condition occurs, the following will happen;

•  Alarm output activates,
•  Built in buzzer sounds,
•  Green LED begins flashing.

The follow alarm conditions are available:

•  Door opened without a valid code entry first. (Door forced alarm)
•  Door not closed by the time the Relay1/Lock output returns to standby status. (Door jammed open alarm)
•  Keypad housing opened. (Tamper alarm)

After the alarm time (set by the installer) has expired, the alarm output and the built in buzzer resets. However, the
flashing green LED continues until the first valid user code is entered into the keypad. This way the user is made aware
that an alarm condition occurred even after the built in buzzer and alarm output have reset.

TO AVOID OVERHEATING OF THE SOLENOID, NEVER USE THIS FUNCTION WITH ELECTRO-MECHANICAL 
STRIKERS or LOCKS!

In cases such as an office park or school gate automation, that needs to temporarily be kept open to allow for peak traffic 
periods, this function can be used. 

This function requires a dedicated code which is set up by the master code holder.

When the bypass code is entered, Relay 1/Lock output will latch on until either the same code is entered again or the free
exit push button is pressed.

While the bypass function is active, no other Relay 1/Lock output user code will release the relay.

This function is also useful where a magnetic lock is installed.

Summary of Contents for EPad

Page 1: ...rbell When multiple incorrect codes have been entered consecutively When Aux code is entered Each relay has its own LED indicator for relay status indication at a glance Relay 1 Lock output can be activated to latch on temporarily while in pulse mode using the unique Bypass code Specifications Operating voltage 12 24v AC DC Maximimum standby current 100mA Maximum load on dry contact relay outputs ...

Page 2: ...tch input terminal connection 6 Relay 2 Aux Output terminal connections 7 System Restore Factory Default dipswitch 8 Bypass Door monitoring dipswitch 9 Bypass Tamper switch monitoring dipswitch 10 Built in tamper switch 1 Remove power 2 Switch System restore switch on 3 Re apply power 4 Wait for buzzer to tone conitinuously 5 Switch System restore switch off All settings and features are now retur...

Page 3: ...nly be DC Mag lock example Strike lock example 4007 4007 470X Use the 47pf capacitor when power is AC LED Indications Power LED Green LED Relay 1 Lock output Amber LED Relay 2 Auxiliary output Red Normal operating mode On relay active On relay active Yellow Programming mode active Off relay inactive Off relay inactive Flashing Alarm activated since last valid user entered exited Enter any valid us...

Page 4: ...determine the length of all user codes Lock Aux and bypass users i e the default master code is 1234 Therefore all user codes will be 4 digits long unless the master code is changed If the master code length is changed after user codes have already been programmed the following will occur Master code shortened the last digits of the user code will be dropped making the user codes the same length a...

Page 5: ... LOCKS When the Bypass code is entered Relay1 Lock output latches on until the bypass code is re entered or when the FRX push button is used Enable the bypass code function Type in Master Code Master Code chime tone 52 1 chime tone Disable the bypass code function Type in Master Code Master Code chime tone 52 0 chime tone Deleting an individual user code Type in Master Code Master Code chime tone ...

Page 6: ...ble bypass mode 52 1 Disabled Disable bypass mode 52 0 Default Set bypass code 52 New unique bypass code None Alarms and Security Enable multiple incorrect code lock out Anti hacking feature 51 to toggle between enabled or disabled Disabled Disable Alarm output mode 55 0 Disabled Door monitoring forced open or jammed open alarm 55 1 Door open time Relay 1 Lock output pulse length Disabled Tamper a...

Page 7: ...m Door not closed by the time the Relay1 Lock output returns to standby status Door jammed open alarm Keypad housing opened Tamper alarm After the alarm time set by the installer has expired the alarm output and the built in buzzer resets However the flashing green LED continues until the first valid user code is entered into the keypad This way the user is made aware that an alarm condition occur...

Page 8: ...isqualify this product from the warranty as laid out above These conditions are non negotiable 1 Any unauthorized non manufacturer modifications to the product or components thereof 2 Any modification to the installation methods described in the installation instructions 3 Any application or use of the product other than the intended use and application prescribed in the product documentation The ...