Power supply voltage:

 230 Vac - 50 Hz

Power absorption on standby:

 0,5 W

Encoder resolution:

 2,7°

Continuous operation time:

 4 min

Connection cable length:

 2,5 m

Operating temperature:

 -20°C

IP Protection rating:

 IP 44

Note

:

– All technical characteristics refer to an ambient temperature of 20°C (± 5°C).
– Nice S.p.a. reserves the right to apply modifications to the product at any 

ti me when deemed necessary, while maintaining the same functionalities and 

in tended  use.

Technical specifications

Disposal of the product

This product constitutes an integral part of the automation system, there-

fore it must be disposed of along with it.

As in installation, also at the end of product lifetime, the disassembly and scrapping 

operations must be performed by qualified personnel. 

This product is made up of different types of material, some of which can be recycled 

while others must be disposed of. Seek information on the recycling and disposal 

systems envisaged by the local regulations in your area for this product category.

Caution!

 - some parts of the product may contain pollutant or hazardous substanc-

es which, if disposed of into the environment, may cause serious damage to the 

environment or physical health.
As indicated by the symbol on the left, disposal of this product in 

domestic waste is strictly prohibited. Separate the waste into cate-

gories for disposal, ac cording to the methods envisaged by current 

legislation in your area, or return the product to the retailer when pur-

chasing a new version.

Caution!

 - Local legislation may envisage serious fines in the event of abusive dis-

posal of this product.

EU declaration of conformity

Note

: This declaration corresponds to the official declaration held at the regis-

tered offices of Nice S.p.a., and in particular to the latest revision available at the 

time of printing of this manual. The text herein has been adapted for editorial 

purposes. A copy of the original declaration may be requested from Nice S.p.a. 

(TV) Italy.

Declaration number:

 402/E STAR T 

 

Revision:

  5  

Language:

 EN

 

Name of manufacturer: 

NICE S.p.A.

Address: 

Via Pezza Alta N°13, 31046 Rustignè di Oderzo (TV) Italy

Person authorised to compile the technical documentation: 

NICE S.p.A.

Type of product: 

Square tubular motor for rolling shutters and awnings

Model / Type: 

E STAR ST 324, E STAR ST 524, E STAR ST 611, 

E STAR ST 1011, E STAR ST 430, E STAR MT 1030, E STAR MT 426, 

E STAR MT 1026, E STAR MT 817, E STAR MT 1517, E STAR MT 3017, 

E STAR MT 4012, E STAR MT 5012, E STAR MKT 1517, E STAR MKT 3017, E 

STAR MKT 5012, E STAR LT 5517, E STAR LT 6517, E STAR LT 7517, 

E STAR LT 8014, E STAR LT 10012, E STAR 12012

Accessories: 

The undersigned, Roberto Griffa, in the role of Chief Executive Officer, declares 

under his sole responsibility, that the product specified above conforms to the 

provisions of the following directives:

• DIRECTIVE 2014/35/EU (LVD)

  –  EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + 

A13:2008 + A14:2010 + A15:2011 

  –  EN 60335-2-97:2006+A11:2008+A2:2010

  –  EN 62233:2008

• DIRECTIVE 2014/30/EU (EMC)

  –  EN 55014-1:2006+A1:2009+A2:2011

  –  EN 55014-2:2015 

  –  EN 61000-3-2:2014, EN 61000-3-3:2013

Oderzo, 

05/04/2017 

      

  

Ing. 

Roberto Griffa

(Chief  Executive  Officer)    

Summary of Contents for E Star LT

Page 1: ...Tubular motor EN Instructions and warnings for installation and use SV Anvisningar och varningar f r installation och anv ndning Nice E Star ST E Star MT E Star MKT E Star LT...

Page 2: ......

Page 3: ...leting the entire memory ref paragraph 5 9 C L N 1 2 3 4 FUSE 1 Brown electric ascent descent phase 2 Black electric descent ascent phase 3 Blue Common usually connected to Neutral 4 Yellow green Eart...

Page 4: ...sal 1 3 Operation warnings This product is not designed to be used by persons including children whose physical sensorial or mental capacities are reduced or with lack of experience or skill unless su...

Page 5: ...p between contacts to ensure complete disconnection in overvoltage category III in compliance with installation regulations the disconnect device is not supplied with the product For electrical connec...

Page 6: ...s without casings The high limit switch 0 or the low limit switch 1 can be memorised at the beginning according to your needs The RDC function cannot be enabled in these cases 01 Use the Up or Down bu...

Page 7: ...and hold the Down button at the same time and wait for the awning to complete a short down movement then release the two buttons 04 Press and hold the Down pushbutton until the awning moves to the re...

Page 8: ...ions 0 and 1 03 5 sec 02 01 04 5 sec THE END 1 1 1 English 6 5 7 Awning with AUTOMATIC hook up of fabric on opening FTC function This function enables automatic connection and disconnection of the awn...

Page 9: ...Press and hold Up and wait for the awning to stop automatically at limit switch 0 do not release the button 03 With the Up button still pressed press and hold the Down button at the same time and wai...

Page 10: ...when the temperature returns to within the normal range WARNINGS FOR DAILY USE OF THE AUTOMATION 6 q When an electric phase is powered the motor does not move Unless a thermal cut out has tripped in w...

Page 11: ...tailer when pur chasing a new version Caution Local legislation may envisage serious fines in the event of abusive dis posal of this product EU declaration of conformity Note This declaration correspo...

Page 12: ......

Page 13: ...4 Att radera hela minnet ref avsnitt 5 9 C L N 1 2 3 4 FUSE 1 Brun fasledare r relse upp t ned t 2 Svart fasledare r relse ned t upp t 3 Bl neutralledare 4 Gul gr n Jord potentialutj mning existerar...

Page 14: ...llande anv ndning Produkten r inte avsedd att anv ndas av barn eller personer vars fysiska sens oriska eller mentala kapacitet r minskad eller av personer med bristf llig erfaren het eller kunskap om...

Page 15: ...getts i denna manual En fr nskiljare ska installeras p produktens elkabel med ett mellanrum mellan kon takterna f r att garantera en total fr nkoppling i versp nningskategori III i enlighet med instal...

Page 16: ...ser utan h ljen Den vre ndl gesbrytaren 0 eller den nedre ndl gesbrytaren 1 kan lagras i b rjan i enlighet med dina behov RDC funktionen kan inte aktiveras i dessa fall 01 Anv nd upp eller ned knappen...

Page 17: ...t Tryck samtidigt p ned knappen och h ll den nedtryckt tills markisen har slutf rt en kort r relse ned t Sl pp sedan upp knapparna 04 Tryck p ned knappen och h ll den nedtryckt tills markisen kommer t...

Page 18: ...isen k ras endast mellan ndl ge 0 och 1 03 5 sec 02 01 04 5 sec THE END 1 1 1 Svenska 6 5 7 Markis med AUTOMATISK sp rrning av markisv v i ppningsl ge FTC funktion Funktionen medger automatisk sp rrni...

Page 19: ...pp knappen och h ll den nedtryckt tills markisen automatiskt stannar vid ndl gesbrytaren 0 sl pp inte upp knappen 03 Forts tt att h lla upp knappen nedtryckt Tryck samtidigt p ned knappen och h ll den...

Page 20: ...mala omr det VARNINGAR G LLANDE DAGLIG ANV NDNING AV AUTOMATISERINGEN 6 q N r en elektrisk fas har tillr cklig str mtillf rsel men motorn g r inte ig ng Om verhettningsskyddet inte har l sts ut i det...

Page 21: ...f ljder enligt lokal lagstiftning EU deklaration om verensst mmelse Obs Denna f rs kran motsvarar den officiella deklarationen hos Nice S p a s rskilt den senaste revisionen som finns tillg nglig vid...

Page 22: ......

Page 23: ......

Page 24: ...www niceforyou com Nice SpA Oderzo TV Italy info niceforyou com IS0081C00MM_26 07 2017...

Reviews: