3
– English
C1
C2
C4
C3
B3
B1
B2
A1
A2
A3
N L
B3
B2
B1
100-240 Vac
50/60 Hz
100-240 Vac
50/60 Hz
100-240 Vac
50/60 Hz
LIGHT
SENSOR
Com.
B3
B1
Step by Step (
▲
g
■
gqg
■
g
...
)
Com.
connect to DMBM
BUS T4
✱
✱
DRY CONTACT
✱
1
B
D
C
2
3
A
E
4
5
6
3
3.1 - Connecting the motor to the mains power
supply
The motor is powered by a permanent connection to the mains. Use
cable “A”
(
fig.
3
) for this connection,
making sure to observe the warnings in full.
3.2 - Connecting accessories and sensors
Only cabled accessories and climate sensors can be connected to the mo-
tor
. For such connections use
cable “B”
, referring to
fig. 3
and the following in-
structions.
– You can connect only one compatible accessory at a time to the
white
and
white-black
cables.
– You can connect only one compatible accessory at a time to the
white-orange
and
white-black
cables.
– Up to 5 tubular motors can be connected to one accessory, respecting the polar-
ity of the signals (connect the
white-black
cables of all motors together as well as
the
white-orange
cables of all motors).
3.2.1 - Connecting push button panels
You can connect either 1 or 2 button panels.
Caution!
- The maximum length of the cables used to connect a wall-mounted pan-
el or a relay is 100 m.
– Model with 1 button
excites an input: the command is either Open or Step-by-
step; the command is memorised with procedure A.7. The panel must be connect-
ed to the
white
and
white-black
wires.
– Model with 2 buttons
excites two inputs: one for the Up command, and one for
the Down command; it is also possible to program the operating logic using pro-
cedure A.5. The
Open
and
Close
inputs are constrained to reach other, in other
words they must be used with the same pushbutton panel (
fig. 3
).
3.3 - Connecting the motor to the DMBM module
To connect the motor to the DMBM module, use
cable “C”
and refer to
fig. 3
.
LEGEND
A
Power cable
D
Electronic motor head
A1
=
Brown
wire
E
Limit switch adjustment buttons
A2
=
Blue
wire
1
Double button
A3
=
White-orange
wire
2
Single button (“Open” or “Step-by-Step” command)
B
Command cable
3
Climate sensor (wired)
B1
=
White
wire
4
Motor mains power disconnector.
B2
=
White-orange
wire
5
Connection to the mains
B3
=
White-black
wire
6
Earth connection
C
Smart-Bus cable
C1
=
Red
wire
C2
=
Yellow
wire
C3
=
Blue
wire
C4
=
Black
wire
EN USA (UL)
A
A1
White
A2
Black
A3
Green/
Yellow-green
**
*
DRY CONTACT
**
THE POWER CABLE IS REMOVABLE
*
*