12
12 - ACTUATOR WIRING
Apollo actuator motor wiring
Connect the Apollo 816 actuator motor leads to the 3-pin
connector as shown below.
Note: If the gate moves in the
opposite direction from what is expected, reverse the
actuator wiring from what is shown. (Red to Pin 3, Black to
Pin 1).
Install the 5 and 3-pin connector into the connection labeled
“Motor 1” on the controller as shown in section 6.10. Install
the 5 and 3-pin and connector into the connection labeled
“Motor 2” for a dual leaf swing gate installation.
1
2
3
816
Actuator
Motor Leads
NOTE: If gate moves in opposite
direction from what is expected,
reverse the motor power lead wiring
Red
Black
Apollo actuator motor wiring
Connect the Apollo 816 actuator motor leads to the 3-pin
connector as shown below.
Note: If the gate moves in the
opposite direction from what is expected, reverse the
actuator wiring from what is shown. (Red to Pin 1, Black to
Pin 3).
Install the 5 and 3-pin connector into the connection labeled
“Motor 1” on the controller as shown in section 6.10. Install
the 5 and 3-pin and connector into the connection labeled
“Motor 2” for a dual leaf swing gate installation.
1
2
3
816
Actuator
Motor Leads
NOTE: If gate moves in opposite
direction from what is expected,
reverse the motor power lead wiring
Black
Red
816 limit switch and smart sensor wiring
Connect the Apollo 816 actuator cable to the 5-pin connector
as shown below. These connections enable the Apollo 816
limit switch and smart sensor inputs into the gate controller.
816 limit switch and smart sensor wiring
Connect the Apollo 816 actuator cable to the 5-pin connector
as shown below. These connections enable the Apollo 816
limit switch and smart sensor inputs into the gate controller.
1
2
3
4
5
1
2
3
4
5
816 Actuator
(with encoder)
816 Actuator
(with encoder)
White: Close limit
Orange: Open Limit
Green: Limit Common
Yellow: Encoder Signal
Blue: Encoder Power
White: Close limit
Orange: Open Limit
Green: Limit Common
Yellow: Encoder Signal
Blue: Encoder Power
Blue
Yellow
Green
Orange
White
Blue
Yellow
Green
White
Orange
12.2 - 816 ACTUATOR WIRING (PUSH TO OPEN)
12.1 - 816 ACTUATOR WIRING (STANDARD)
13 - GATE BRACKET MOUNTING
Pull to Open only:
Activate push button on the side of the control box and extend the actuator until it stops (leave actuator
retracted for PUSH TO OPEN).
WARNING:
Do not let extension tube rotate as it extends. Do not insert fingers or tools in the hole at the end of the extension
tube.
Connect the gate bracket to the end of the extension tube
with supplied 1/2” x 3” bolt. With the gate in the closed
position, place the gate bracket on the gate and mark
placement or secure with a clamp. Unbolt and remove the
extension tube from the bracket and weld or bolt the bracket
to the gate using 3/8” bolts, lock washers, and nuts.
Bolt the actuator to the gate bracket as shown.
Tip:
Tack weld or C clamp at first if uncertain about location.
Run the unit through a complete cycle to insure proper
operation then mount permanently.
Summary of Contents for 15501K
Page 2: ......
Page 28: ...28 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...