18 - ACCESSORY INPUTS AND OUTPUTS 

GATE OPERATOR ACCESSORY INPUTS:
Auxiliary Inputs 1 (16) and 2 (18):

 These digital inputs may be connected 

to the digital outputs of accessories and programmed to activate or control 

the gate operator in a number of different modes. Shorting the pins through a 

dry contact activates the programmed settings for these inputs. These inputs 

are programmed in the “FUNCTION Auxiliary I/O” menu. 

SAFETY LOOP Input:

 (22) Dry contact input that can be programmed for an 

inductive safety loop or photo-eye detector. Shorting pin 22 to GND reverses 

a closing gate to the full open position. The opened gate is held opened for 

as long as the LOOP input is active. 

SHADOW (LOOP 1) Input:

 (24) Dry contact input that can be programmed 

for an inductive safety loop or photo-eye detector. Shorting the LOOP 1 input 

(24) to GND maintains an OPEN gate fully open and a CLOSED gate fully 

closed until deactivated. 
Setting the LOOP1 input to “Photo Mode” causes the moving gate to stop, 

then reopens the gate when the LOOP1 input is deactivated. 

ENTRAPMENT (LOOP 2) Input:

 (26) Dry contact input that can be 

programmed for an inductive safety loop or photo-eye detector. Shorting the 

LOOP2 input (26) to GND while the gate is opening cause the gate to close 

to the fully closed position. This loop input is intended for use with safety 

sensors to prevent entrapment between the opening gate and an adjacent 

wall or structure. 

Edge Input:

 (28) This input may be configured as “DIGITAL” or “ANALOG” 

as required by the sensor type. When configured as “DIGITAL”, this is a dry 

contact input; otherwise when configured as “ANALOG”, the input must 

measure 8200ohms. When the input is activated it stops the gate regardless 

of direction of travel, momentarily reverses it then stops. 

Exit Input:

 (30) Dry contact input for a vehicle exit sensor. Shorting this 

input to GND opens gate from the closed position and holds gate open with 

maintained input or reverses gate if closing. 

Fire Input:

 (32) Dry contact input for a fire department control switch. Opens 

the gate and holds the gate open until the control switch is deactivated. This 

input is “hold to run”. Auto-close is disabled when this input is activated. Also 

clears hard shutdown. 

GUARD STATION
Guard Station Open:

 (34) Dry contact input for a guard station open switch. 

Momentarily shorting the digital input to GND opens the gate to the full open 

position with the subsequent auto-close feature enabled. 

Guard Station Stop:

 (35) Dry contact input (Normally Closed) for a guard 

station stop switch. Momentarily opening this input stops the opening gate at 

its current position. While this input is activated, all other inputs are disabled 

and are not functional. 

Guard Station Close:

 (36) Dry contact input for a guard station close 

switch. Momentarily shorting the digital input to GND closes the gate (master 

and slave). 

RADIO
Radio Open:

 (39) Dry contact input for an accessory radio open switch. 

Momentarily shorting the digital input to GND opens the gate to the full open 

position with the subsequent auto-close feature enabled. 

Radio Close:

 (40) Dry contact input for an accessory radio close switch. 

Momentarily shorting the digital input to GND closes the gate. 

Radio Input:

 Open/Close: (39 and 40) If you tie open and close together the 

unit will operate as a Step by Step command each time the input is shorted 

to GND, it will either OPEN, STOP or CLOSE.

18.1 - Outputs 

Figure - BOARD OUTPUTS 

GATE OPERATOR ACCESSORY OUTPUTS:
OUT1 and OUT2:

 Individual, isolated relays provide COMMON, NORMALLY 

OPEN, and NORMALLY CLOSED dry contacts for switching accessories 

based on programming of the “Auxiliary IO” function. These outputs are 

programmed in the “FUNCTION Auxiliary I/O” menu. 

Magnetic Lock:

 Provides fused power (1.85A max) and isolated relay 

COMMON, NORMALLY OPEN, and NORMALLY CLOSED dry contacts for 

electrically powered and maintained magnetic locks. The output time for 

magnetic lock activation/deactivation may be adjusted from 0 to 5 seconds. 

Lamp:

 Provides fused power (1.85A max) to drive a flashing warning lamp 

to indicate gate operation. This output is active when the gate is operating 

(Opening and Closing). Lamp Delay sets the amount of time the lamp 

accessory output is activated prior to gate movement. Settings from 0 to 5 

seconds with a step of 0.5 seconds. 

Alarm:

 Provides fused power (0.5A @ 12VDC) to drive an alarm siren 

to signal the occurrence of a hard shutdown, caused by 2 consecutive 

entrapment events (signals). This alarm output is reset by pressing the “Reset 

Hard Shutdown” button on the front panel or activating the “FIRE” input. 

18.2 - Inputs 

Figure - INPUTS 

Summary of Contents for 15501K

Page 1: ...Nice Apollo Swing Gate Opener Vehicular Swing Gate Operator Revision 1 0 0 0_2 2014 Model 15501K Model 16501K...

Page 2: ......

Page 3: ...BRACKET MOUNTING 12 14 LIMIT AND MOTOR CONNECTION TO THE BOARD 13 15 LIMIT SWITCH ADJUSTMENT 13 16 SETTING LIMIT SWITCHES 14 17 LEARNING MODE 15 18 ACCESSORY INPUTS AND OUTPUTS 16 18 1 Outputs 16 18...

Page 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Page 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Page 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Page 7: ...t any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of th...

Page 8: ...Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections Control Box 11111B 816 Actuator with 8 harness 816X Actuator with 38 harness Supplied with 16501K Pivot...

Page 9: ...geometry and rate of speed of the gate it is critical that the measurements below are followed The pivot arm may need to be cut to achieve the correct placement of the actuator mounting hole Measureme...

Page 10: ...tuator mounting hole Measurements are taken from the center of pivot of the gate hinge 8 2 Vertical position of pivot arm DIRECTION OF OPENING GATES CLOSED HINGE POST HINGE POST LEFT HAND SWING RIGHT...

Page 11: ...wards a red LED will illuminate below the terminal If solar power is to be used it will be necessary to program control board for STANDBY operation See section 16 for information on STANDBY mode Batte...

Page 12: ...as shown below These connections enable the Apollo 816 limit switch and smart sensor inputs into the gate controller 816 limit switch and smart sensor wiring Connect the Apollo 816 actuator cable to...

Page 13: ...l the 5 and 3 pin connector for motor 1 into the connection labeled Motor 1 on the controller as shown For a dual gate installation install the 5 and 3 pin and connector for motor 2 into the connectio...

Page 14: ...range and white limit wires CLOSE LIMIT Red CLOSE LED 3 Using the CLOSE button on the front of the Control Board hold the button down until the gate reaches the fully intended closed position 4 Adjust...

Page 15: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Page 16: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Page 17: ...cting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receive...

Page 18: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Page 19: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 21 2 Magnetic lock connection...

Page 20: ...ty equipment and connections Clean equipment and connections 22 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 22 7 Poor mechan...

Page 21: ...Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Figure LAYOUT FOR PHOTOCELLS Loop Safety Loop Safety Loop Shadow Loop Exit...

Page 22: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Page 23: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Page 24: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 26 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Page 25: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Page 26: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Page 27: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Page 28: ...28 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...

Page 29: ...29 1 1 2 2 A A B B COMPANY NICE APOLLO NAME ACTUATOR GENERAL VIEW 43 17 ACTUATOR CLOSED 7 38 5 74 31 41 4 0 3 0 1 66 7 01...

Page 30: ...LE POLE 1115 1 4 SWITCH PUSH BUTTON CNTRL BOX 1119 1 5 1050 CIRCUIT BOARD 1050 1 6 1050 BOARD MOUNT KIT 10055090 1 7 NICE RECEIVER 318NPI 1 8 1 1 2 2 A A B B TITLE Company 2 6 8 3 7 4 5 1 Note Control...

Page 31: ...SPUR GEAR A2017 1 3 LIMIT SCREW A2019 1 4 LIMIT TOWER BUSHING A2009 1 5 MAIN SCREW A2018 1 6 SEAL HOUSING ALUMINIUM A2064 1 7 BEARINGS A2087 1 8 COVER TUBE A2091 1 9 AC GEAR NUT A2006 1 10 SEAL A2025...

Page 32: ...A2012K 1 7 LIMIT CAP SEAL A2010 2 8 STRAIN RELIEF A2029 1 9 SMART SENSOR 816 Only A2072 1 10 HARNESS See Note 1 11 1 1 2 2 A A B B Company NICE APOLLO Description Actuator Back Housing 7 8 11 9 1 10...

Page 33: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Page 34: ...34...

Page 35: ...bstruction sensing feature and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the...

Page 36: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...

Reviews: