op. mode 4.2
auto
manual
add. heat only
op. mode
Setting range: auto, manual, add. heat
only
Default value: auto
functions
Setting range: compressor, addition,
heating, cooling
The electric boiler/indoor module operating mode is usually set to “auto”. It is
also possible to set the electric boiler/indoor module to “add. heat only”, when
only additional heat is used, or “manual” and then select what functions are to
be permitted.
Change the operating mode by marking the desired mode and pressing the OK
button. When an operating mode is selected, the system shows what is permitted
in the electric boiler/indoor module (crossed out = not permitted) and selectable
alternatives are presented to the right. To select which selectable functions are
to be permitted or not, mark the function using the control knob and press the
OK button.
Operating mode auto
In this operating mode, the electric boiler/indoor module automatically selects
what functions are permitted.
Operating mode manual
In this operating mode you can select what functions are permitted. You cannot
deselect "compressor" in manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active, only additional heat is used.
Caution
If you choose mode "add. heat only" the compressor is deselected and
there is a higher operating cost.
Caution
You cannot change from only additional heat if you do not have a heat
pump connected (see Menu 5.2.2).
NIBE VVM 225
Chapter 3 | VVM 225 – at your service