TIP
If you wish to set similar scheduling for every day of the week start
by filling in “all” and then changing the desired days.
TIP
Set the stop time earlier than the start time so that the period extends
beyond midnight. Scheduling then stops at the set stop time the day
after.
Scheduling always starts on the date that the start time is set for.
ADVANCED
advanced 2.9
periodic increase
hot water recirc.
Menu
advanced
has orange text and is
intended for the advanced user. This
menu has several sub-menus.
Menu
2.9
PERIODIC INCREASE
periodic increase 2.9.1
activated
period
start time
Next periodic increase
days
period
Setting range: 1 - 90 days
Default value: 14 days
start time
Setting range: 00:00 - 23:00
Default value: 00:00
Menu
2.9.1
To prevent bacterial growth in the water heater, the heat pump and the immersion
heater can increase the hot water temperature for a short time at regular intervals.
The length of time between increases can be selected here. The time can be
set between 1 and 90 days. Factory setting is 14 days. Tick/untick "activated" to
start/switch off the function.
NIBE VVM 225
Chapter 3 | VVM 225 – at your service
50