Transport
S135 should be transported and stored vertically in a
dry place.
Assembly
• S135 is installed freestanding on brackets or a suitable
flat surface indoors. Noise from the circulation pump,
fan and compressor can be transferred to the bracket
or the surface on which S135 is placed. Use the
product’s adjustable feet to obtain a horizontal and
stable set-up.
30 - 50 mm
30 - 50 mm
15 - 40 mm
20-55 mm
• S135 must be positioned with the back towards a wall.
Install the brackets or position S135 against an outside
wall, ideally in a room where noise does not matter,
in order to eliminate noise problems. If this is not
possible, avoid placing it against a wall behind a bed-
room or other room where noise may be a problem.
• Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
• Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
INSTALLATION AREA
Leave a free space of 800 mm in front of the product.
Leave free space between S135 and wall/other ma-
chinery/fittings/cables/pipes etc. It is recommended that
a space of at least 10 mm is left to reduce the risk of
noise and of any vibrations being propagated.
* Depending on whether the panels can be removed or
not.
NOTE
Ensure that there is sufficient space (300 mm)
above S135 for installing ventilation hoses.
7
Chapter 2 | Delivery and handling
NIBE S135
2 Delivery and handling