Docking
23
For the Installation engineer
FIGHTER 1310
AV
Shutoff valve
BV
Check valve
VVB
Water heater
SF
Particle filter
SÄV
Safety valve
FG
Flow sensor
VVG
Hot water sensor
UG
Outside temperature sensor
RG
Return sensor
HR
Auxiliary relay/Contactor with bypass
VXV
Reversing valve
RV
Control valve
A
Heat pump module A
B
Heat pump module B
NV
Level vessel
BK/JK
Rock collector/Ground collector
EXP
Expansion vessel
with the requisite safety equipment.
VVB/ACK Accumulator with water heater
FIGHTER 1310 gives priority to hot water charging at
half power (heat pump module B) via a reversing
valve (VXV). When the water heater/accumulator tank
(VVB/ACK) is fully charged the reversing valve (VXV)
switches over to the heating circuit. When there is a
heat requirement, module A starts first. For larger
requirements, module B takes care of the heating. The
electric boiler is connected automatically when the
energy requirement exceeds the capacity of the heat
pump.
If VVB/ACK is fitted with an immersion heater (IU) and
a junction box (K11) the Extra hot water function can
be used. A by-pass contactor is recommended.
The accessories VST 11, IU and K11 are available for
this option.
B
A
Cirk.pump
Värmepump
Varmvatten
Tillsatsvärme
Larm
Kontrollera
att vatten
finns i pan-
nan innan
1
R
0
HR
T
EXP
SÄV
Elkassett/
Elpanna
AV
FG
RG
BV
BV
BV
VXV
RV
RV
SF
SF
AV
SÄV
VVG
VVB / ACK
VVB
UG
SF
P
EXP
AV
KB-r
KB-f
Option 2 FIGHTER 1310 docked
with an electric boiler and water heater (floating condensation)
Electric
boiler