Condensation
The condensation water trough collects and leads away
most of the condensation water from the heat pump.
NOTE
It is important to the heat pump function that
condensation water is led away and that the
drain for the condensation water run off is not
positioned so that it can cause damage to the
house.
NOTE
Pipe with heating cable for draining the con-
densation water trough is not included.
NOTE
To ensure this function the accessory KVR 10
should be used.
NOTE
Condensation runoff should be checked regu-
larly, especially during the autumn. Clean if
necessary.
NOTE
The electrical installation and wiring must be
carried out under the supervision of an author-
ised electrician.
■
The condensation water (up to 50 litres/24 hrs) that
collects in the trough should be routed away by a
pipe to an appropriate drain, it is recommended that
the shortest outdoor stretch possible is used.
■
The section of the pipe that can be affected by frost
must be heated by the heating cable to prevent
freezing.
■
Route the pipe downward from F2120.
■
The outlet of the condensation water pipe must be
at a depth that is frost free or alternatively indoors
(with reservation for local ordinances and regula-
tions).
■
Use a water trap for installations where air circulation
may occur in the condensation water pipe.
■
The insulation must seal against the bottom of the
condensation water trough.
Recommended alternative for leading off
condensation water
Stone caisson
LEK
Frostfritt djup
F2120
Frost proof
depth
If the house has a cellar the stone caisson must be po-
sitioned so that condensation water does not affect
the house. Otherwise the stone caisson can be posi-
tioned directly under the heat pump.
The outlet of the condensation water pipe must be at
frost free depth.
Drain indoors
Water seal
Joint
The condensation water is lead to an indoor drain
(subject to local rules and regulations).
Route the pipe downward from F2120.
The condensation water pipe must have a water seal
to prevent air circulation in the pipe.
NIBE™ F2120
Chapter 2 |
Delivery and handling
12
Summary of Contents for F2120-12
Page 1: ...Installer manual LEK NIBE F2120 8 12 16 20 Air water heat pump IHB GB 1621 1 331385...
Page 2: ......
Page 15: ...Removing the side cover LEK 15 Chapter 2 Delivery and handling NIBE F2120...
Page 55: ...Electrical circuit diagram 1x230V 55 Chapter 10 Technical data NIBE F2120...
Page 56: ...NIBE F2120 Chapter 10 Technical data 56...
Page 57: ...57 Chapter 10 Technical data NIBE F2120...
Page 58: ...NIBE F2120 Chapter 10 Technical data 58...
Page 59: ...3x400V 59 Chapter 10 Technical data NIBE F2120...
Page 60: ...NIBE F2120 Chapter 10 Technical data 60...
Page 61: ...61 Chapter 10 Technical data NIBE F2120...
Page 62: ...NIBE F2120 Chapter 10 Technical data 62...
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......