20
100
100
500
20
500
50
100*
30
20 mm Luftspalt
GB
96
!
20 mm Air gap
Diagram of aerated wall
Two calcium silicate board
battens ensure that the air
space is maintained.
Wall made of combustible material
Aerated wall, comprising at least a 50 mm
calcium silicate board and an air space. There
must be a 20 mm air space between the
building board and the combustible wall. The
air space must allow air to flow freely along
the lower and upper edges (see diagram to the
right).
Wall made of non-combustible material that
is not in contact with combustible material
and therefore has no minimum thickness
requirement.
Unless otherwise stated, these
are the minimum dimensions.
Final inspection of the installation
It is extremely important that the installation is inspected by an authorised inspection body
before the stove is used. You should also read the “Lighting instructions” before lighting the stove
for the first time.
RECESSING THE INSERT
* The distance between the exhausts on
the sides and a combustible wall behind
should be at least 100 mm.
Recess example
Summary of Contents for Contura Ci60