GB
16
The minimum distance in front of the
stove opening to combustible parts
of the building or interior decoration
must be at least 1,1 m.
The dimension diagrams only show
the minimum permitted installation
distances for the stove. When con-
necting to a steel flue, also note the
safety distance requirements of the
flue. The safety distance between an
uninsulated flue and a combustible
part of the building should be at least
450 mm.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the following
installation distances do not apply.
See the separate turntable installation instructions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
E = minimum height to sloped ceiling
from the centre of the chimney
F = height from floor to knockout in
the pedestal
Permitted area for
combustible parts
of the building
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
INSTALLATION AGAINST COMBUSTIBLE WALLS
INSTALLATION AGAINST FIREWALLS
C886 / C886G Style
465
Ø 490
1110
2100
D 413
Combustible roof
365
183
245
46
A 1065
B 976
C 430
F 344
Ø150
Air inlet Ø67
432
663
797
200
200
Combustible wall
283
515
750
750
50
50
585
Fire-retardant wall of
brick or concrete
432**
253
70
200**
700
1000
Fire-retardant wall of
brick or concrete
732
500
400
400
283
100
Combustible wall
2100
E 630
100