GB
16
!
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the following installation distances do not
apply.
See the separate turntable installation
instructions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
E = minimum height to sloped ceiling
from the centre of the chimney
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney by
10 mm.
Permitted area for
combustible parts
of the building
INSTALLATION AGAINST COMBUSTIBLE WALLS
INSTALLATION AGAINST FIREWALLS
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
1066
495
2000*
D 368
74
201
Combustible roof
140
100
B 920*
A 1015*
C 380
35
440
Air inlet Ø67
Ø150
310
100
595
740
Combustible wall
260
50
545
642
800
800
Fire-retardant wall of
brick or concrete
450**
850
1100
200**
190
50
Fire-retardant wall of
brick or concrete
750
500
400
400
240
100
Combustible wall
C510
2000
E 530
100