Quality approval

The stove has been tested by the Swedish 
National Testing and Research Institute and 
meets the applicable regulations for CE mark-
ing and the stricter requirements for P mark-
ing. The stove also meets the most stringent 
environmental requirements and is Swan 
marked.
Certificate number for P Marking: 22 03 06
Swan marking: 358 001

Manufacturer’s assurance

Manufacture of the product has taken place in 
accordance with those documents which are 
the basis for the relevant type approval certifi-
cation and the required manufacturing checks.

Requirements for flue

The chimney must be dimensioned for at 
least 350° C for both top connection directly 
upwards and connection directly backwards 
from the rear of the stove.

Warning

During operation, certain surfaces of the 
stove become very hot and can cause burn 
injury if touched.
Be aware of the strong heat radiated 
through the hatch glass. 
Placing flammable material closer than the 
safe distance indicated may cause a fire.
Pyre lighting can cause quick gas ignition 
with the risk of damage to property and 
personal injury. 

NOTE!

Report installation of a stove to your local 
authority.
The owner of the house is personally respon-
sible for ensuring compliance with the manda-
tory safety requirements and must have the 
installation approved by a qualified inspector.
Your local chimney sweep must also be 
informed about the installation as this will 
affect the routines for regular chimney-sweep-
ing services.

CONTURA

In accordance with standards below
marking was affixed:
European Standard:
SE Quality Certification, P-marked:
NO Standard NS 3059:
DK Standard:
DE and AT Standard DIN 18 891
and Art 15a B-VG:
Type:
Nominal Output:
Fuel:
Minimun draught:
Flue gas temerature:
Energy efficiency:
Emission of CO in cumbustion products:
Distance to cumbustible wall (mm):

Production number:

Follow the installation instructions.
Use only recomended fuels
NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN

2006
EN 13240
Cert no 220306
SINTEF 043-104
598DS/EN 13240 plus

RO-9101319
C655/C685
6 kW
Wood
12 Pa
310°C
80%
< 0,12%
Behind 100
Beside 520 (200)
Corner 95
7090300236

CONTURA

NIBE AB SE-85 21 Markaryd Sweden

Type:

Production no.

600-series
7090300236

378

001

NO

RD

IC ECOLAB

EL

Certifierad

Certifikat nr

22 03 06

EU declaration re-
garding agreement

Product covered by this declaration

Product type

 

Stove lit with solid fuels

Type designation

 

Contura 500 series

Type according to standard

  SS-EN 13240

Area of use

 

Heating residences

Fuels

 

Wood

Special conditions

 

None

Manufacturer

Name

 

NIBE AB/NIBE Stoves

Address

 

Box 134, Skulptörvägen 10, SE-285 23 MARKARYD

Location of manufacture

 

Markaryd

Manufacturing check by approved body

Name

 

SP, Swedish National Testing and Research Institute

Address

 

Box 857, SE-501 15 BORÅS

Report no. / date

 

0402-CPD-220318 / 20061102

Niklas Gunnarsson
Business area manager NIBE Brasvärme

Appendices

•  Assembly and installation instructions

GB

Summary of Contents for Contura 580W

Page 1: ...Installation Instructions 511911 IAV SE EX 0740 1 Contura 580W Installationsanvisning 2 Monteringsvejledning 10 Installasjonsanvisning 20 Installation Instructions 30 SE DK NO GB ...

Page 2: ...design and long service life The Contura 500 series also has combustion that is both environmentally friendly and efficient for the best heat production Read the installation instructions carefully before you begin installation and the separate lighting and user instructions before you light the fire Table of contents General 32 Installation distance to walls and ceiling 33 Supply of combustion ai...

Page 3: ...weep must also be informed about the installation as this will affect the routines for regular chimney sweep ing services CONTURA In accordance with standards below marking was affixed European Standard SE Quality Certification P marked NO Standard NS 3059 DK Standard DE and AT Standard DIN 18 891 and Art 15a B VG Type Nominal Output Fuel Minimun draught Flue gas temerature Energy efficiency Emiss...

Page 4: ...ys check with an authorised chimney sweep that the installation method is an approved method and that the chimney walls have sufficient support before starting installation Hearth plate To protect the floor from any embers the stove must be supplied with a hearth plate If the floor under the stove is flammable it must be protected by a non flammable material The hearth plate can consist of natural...

Page 5: ...om floor to supply air opening D height from floor to lower edge of hatch Brandmur av tegel eller betong Brännbar vägg 750 500 155 16 454 100 200 300 400 60 160 260 360 712 min 1000 496 Brännbart tak Brandmur av tegel eller betong 320 70 155 16 454 Tilluftsstos Ø67 88 Utv Ø150 552 47 Dimensions 580W Indirect air supply through the external wall Supply of combustion air Combustion air can be suppli...

Page 6: ... these components uninstalled until the stove has been screwed to the wall and the surround kit has been installed Reinstall the components in reverse order Unpacking Leave the stove body screwed in place on the pallet Place supplied components to one side Dismantle all the loose components from the stove body grate disc fire box surround and heat deflector under the stove body Important The stove...

Page 7: ...l to the flue Make a 180 mm diameter hole Fold in the tabs on the connector so that they create a stop for the flue pipe Then cement in the connector with fireproof mortar not supplied Allow the mortar to dry before installing the back plate Important Take care when making holes to prevent cracks from forming outside the hole as this affects the rigidity of the stove mounting The hole should not b...

Page 8: ...ney breast using the 4 supplied concrete screws Screws that do not tighten must be considered useless and be moved to new holes Insert the connection pipe into the wall connector towards the folded tabs Ø 8 mm 50 mm Check that the pipe protrudes 50 mm from the back plate and caulk between the connection pipe and the connector in the wall using caulking rope If further sealing material is required ...

Page 9: ...ion brackets on the stove body using 2 screws Detach the stove body from the leg by unscrewing the 4 screws Lift the stove body from the leg and suspend the brackets on the body above the back plate s upper mounting angle GB ...

Page 10: ...at the stove connector slides into the connection pipe Lock the stove body using 2 screws at the upper edge Check that the stove body is suspended vertically If necessary the stove body can be adjusted forwards at the lower edge using two adjuster screws at the lower edge Lock the stove body using 2 screws at the lower edge GB ...

Page 11: ...side of the protective plate Then screw the protective plate se curely into place with the plates turned downwards Assembling the stove top Lay the soap stone top or Steel top cast iron top in place remember to handle with care Finish by placing the hot air grille and cover on the soap stone top Important Before the stove is used it must be inspected by an authorised chimney sweep Read the Instruc...

Page 12: ...42 NIBE AB NIBE Brasvärme Box 134 285 23 Markaryd www contura eu ...