background image

Electrical connection ACVM 270

NOTE

All electrical connections must be carried out by an

authorised electrician.

Electrical installation and wiring must be carried out

in accordance with the stipulations in force.

ACVM 270 must not be powered when installing ACK

22.

The electrical circuit diagram is at the end of these installation
instructions.

Following cables for ACK 22 are used in this kit: 0101 to
0112.

1.

The supplied relay card (AA7) is installed on the existing
relay card (AA6) using the plastic turrets, see image be-
low.

2.

Connect the edge connector wiring between the sup-
plied relay card (AA7) and relay card (AA6) as illustrated
below.

HAHN

LEK

Relay card, -AA6

Relay card, -AA7

3.

The corresponding wiring with flat pin sleeves and zero
numbers 0101 to 0103 are installed as follows:

Brown cables with zero number 0101 and 0102 to
flat pin AA7:37.

-

Brown cables with zero number 0102 and 0103 to
flat pin AA7:39.

-

Brown (single) cable with zero number 0103 to flat
pin AA7:41.

-

4.

Mount the terminal blocks, label and strain relief on the
mounting plate. Screw the plate into place with two
accompanying M5 self-tapping torx screws, see image
below.

M5, self-tapping torx

screws

Electrical connection,

X6

PE

From accessories

Electrical

connection,

X6

Space for

AA7

AA6

PE2

7

ACK 22

GB

Summary of Contents for ACK 22

Page 1: ...031263 ACK 22 MONTERINGSANVISNING KABELKIT ACK 22 TILL ESV 22 ELLER VCC 22 SE INSTALLATION INSTRUCTIONS CABLE KIT ACK 22 FOR ESV 22 OR VCC 22 GB MONTAGEANLEITUNG KABELSET ACK 22 F R ESV 22 ODER VCC 2...

Page 2: ......

Page 3: ...270 i NIBE SPLIT Inneh ll Kabelsats 1 st Torxskruv M5 sj lvg ngade 2 st Buntband 5 st Rel kort med kablage AA7 1 st Etikett 1 st Kopplingsplint 2x1 pol X6 1 st Kopplingsplint 2x1 pol PE X6 1 st Koppli...

Page 4: ...t kopplas in mellan det medf ljande rel kortet AA7 och rel kort AA6 enligt bild nedan H A H N LEK Rel kort AA6 Rel kort AA7 3 Det sammanh ngande kablaget med flatstifthylsor och nollnummer 0101 till 0...

Page 5: ...derplint X6 2a 5 10 0108 0109 0110 0111 0112 AA6 X6 Kant kontakt 7 8 6 3 2 1 4 5 Kantkontakt H A H N LEK LEK Sp rning 6 De vriga enskilda ledarna anslutes enligt f ljande Brun ledare med nollnummer 01...

Page 6: ...270 in NIBE SPLIT Contents Cable set 1 x Torx screw M5 self tapping 2 x Cable ties 5 x Relay card with wiring AA7 1 x Label 1 x Terminal block 2x1 pole X6 1 x Terminal block 2x1 pole PE X6 1 x Termina...

Page 7: ...the edge connector wiring between the sup plied relay card AA7 and relay card AA6 as illustrated below H A H N LEK Relay card AA6 Relay card AA7 3 The corresponding wiring with flat pin sleeves and ze...

Page 8: ...able with zero number 0112 to spring terminal X6 2a 5 10 0108 0109 0110 0111 0112 AA6 X6 Kant kontakt 7 8 6 3 2 1 4 5 Edge connector H A H N LEK LEK Guide pin 6 Connect the other individual wires as f...

Page 9: ...in den Inhalt Kabelsatz 1 St Torxschraube M5 selbstschneidend 2 St Kabelbinder 5 St Relaiskarte mit Kabeln AA7 1 St Etikett 1 St Anschlussklemme 2x1 pol X6 1 St Anschlussklemme 2x1 pol PE X6 1 St Ansc...

Page 10: ...l f r den Eckkantenstecker werden mit der beiliegenden Relaiskarte AA7 und der Relaiskarte AA6 verbunden siehe Abbildung unten H A H N LEK Relaiskarte AA6 Relaiskarte AA7 3 Die zusammenh ngenden Kabel...

Page 11: ...an Federklemme X6 2a 5 10 0108 0109 0110 0111 0112 AA6 X6 Kant kontakt 7 8 6 3 2 1 4 5 Eckkantenstecker H A H N LEK LEK Nut 6 Die restlichen einzelnen Leiter werden wie folgt ange schlossen Brauner L...

Page 12: ...Elschema Wiring diagram Elektrischer schaltplan ACK 22 ACK 22 12...

Page 13: ...13 ACK 22...