Appendix B
5B Series Module Data Sheets
SC-2311 User Manual
B-26
ni.com
Convenience Features
A series output switch eliminates the need for external multiplexing in many applications.
The switch is turned on by an active-low enable input. The enable input should be grounded
to power common if the output need not be switched, as on the 5B01 and 5B08
backplanes
.
Figure 1. 5B37 Functional Block Diagram
Input Types
Thermocouple Types :
J, K, T, E, R, S, B, N, C
Output Range
0 to +5 V
(-5 V to +5 V - custom)
Figure 2. 5B37 Input Field Connections