Verifying the Kit Contents

Figure 1. PXIe-5840 Kit Contents

1

2

4

6

7

5

3

NI PXIe-5840

Vector Signal T

ranscei

ver

9 kHz – 6 GHz, 1 GHz BW

PFI 0

DIO

REF
OUT

REF

IN

RF IN

+33 dBm MAX

50 

Ω

RF OUT

Rever

se P

ower

+33 dBm MAX

ACCESS     A

CTIVE

LO OUT

50 

Ω

LO OUT

50 

Ω

LO IN

+15 dBm MAX
50 

Ω

LO IN

+15 dBm MAX
50 

Ω

50 

Ω

50 

Ω

ESD
SENSITIVE

1. PXIe-5840 Module
2. Screwdriver, Part Number 772006-01
3. SMA Driver Bit, Part Number 780895-01
4. Driver Software DVD

5. Read Me First: Safety and Electromagnetic

Compatibility

6. Maintain Forced-Air Cooling Note to Users
7. PXIe-5840 Getting Started Guide

Other Equipment

There are several required items not included in your device kit that you need to operate the
PXIe-5840. Your application may require additional items not included in your kit to install or
operate your device.

Required Items

A PXI Express chassis and chassis documentation. For more information about
compatible chassis options, visit 

ni.com/info

 and enter the Info Code 

pxiechassis

.

A PXI Express embedded controller or PC with MXI controller system that meets the
system requirements specified in this guide and chassis documentation.

Optional Items

PXI Chassis Slot Blocker kit (NI part number 199198-01)

SMA (m)-to-SMA (m) cables

SMA (m)-to-MMPX (m) cables

MMPX (m)-to-MMPX (m) cables

OCuLink x4, 1 m cable

1

1

Using an OCuLink x4 cable supplied by another manufacturer is not recommended.

4

  | 

ni.com

  | 

PXIe-5840 Getting Started Guide

Summary of Contents for PXIe-5840

Page 1: ...on Contents Electromagnetic Compatibility Guidelines 2 Verifying the System Requirements 2 Unpacking the Kit 2 Preparing the Environment 3 Verifying the Kit Contents 4 Other Equipment 4 Choosing and I...

Page 2: ...National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and acces...

Page 3: ...C Operating relative humidity 10 to 90 noncondensing IEC 60068 2 56 Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Caution Clean the hardware with a s...

Page 4: ...veral required items not included in your device kit that you need to operate the PXIe 5840 Your application may require additional items not included in your kit to install or operate your device Req...

Page 5: ...e standard IVI based functionality needed for most vector signal analyzer and vector signal generator applications You can use NI RFSA and NI RFSG instrument driver FPGA extensions to customize the de...

Page 6: ...ice can cool itself effectively This document is also available at ni com manuals The PXIe 5840 is a two slot module with two backplane connectors The module must be installed into two adjacent chassi...

Page 7: ...e it into the empty compatible slots Ensure the base engages with the guides in the chassis Figure 3 PXIe 5840 Module Installation 1 2 3 ESD SENSIT IVE NI PX Ie 5 646 R Vec tor Sig nal Tran sce iver 6...

Page 8: ...only while the PXIe 5840 is powered on Applying external signals while the device is powered off may cause damage Ensure you are properly grounded when manipulating cables or antennas connected to the...

Page 9: ...l NI PXIe 5840 Vector Signal Transceiver 9 kHz 6 GHz 1 GHz BW PFI 0 DIO REF OUT REF IN ESD SENSITIVE RF IN 33 dBm MAX 50 RF OUT Reverse Power 33 dBm MAX 50 LO OUT 50 LO OUT 50 LO IN 15 dBm MAX 50 LO I...

Page 10: ...MMPX f REF OUT Output terminal that can export a 10 MHz Reference Clock or the 156 25 MHz Data Clock MMPX f PFI 0 Programmable function digital I O DIO connector for use with triggers or events MMPX f...

Page 11: ...om the device to monitor the device status or transferring data to from the device Green The device is controllable through the software ACTIVE Off The device is idle Solid green The device is generat...

Page 12: ...I RIO device in your system resource identification of your NI RIO devices may change Whenever any of these changes occur verify resource identification of all your NI RIO devices in MAX and if necess...

Page 13: ...you self calibrate the module 1 Launch the NI RFSA or NI RFSG Soft Front Panel by navigating to Start All Programs National Instruments Driver Driver Soft Front Panel 2 Click Device System Calibratio...

Page 14: ...ectory and import library files located in one of the following directories Windows 10 32 bit 8 1 32 bit 7 32 bit NIDir Shared ExternalCompilerSupport C include Windows 10 64 bit 8 1 64 bit 7 64 bit 3...

Page 15: ...iles x86 IVI Foundation IVI Microsoft Visual C C Use the header files located in the IVIROOTDIR32 Include directory and import library files located in the IVIROOTDIR32 Lib directory where IVIROOTDIR3...

Page 16: ...R32 is one of the following directories Windows 10 32 bit 8 1 32 bit 7 32 bit Program Files IVI Foundation IVI Windows 10 64 bit 8 1 64 bit 7 64 bit Program Files x86 IVI Foundation IVI Microsoft NET...

Page 17: ...ams National Instruments NI RFSG NI RFSG Soft Front Panel to launch the NI RFSG Soft Front Panel 3 Select the device identifier assigned to the PXIe 5840 in MAX in the Device drop down menu 4 Click th...

Page 18: ...nd NI RIO FPGA Device nodes and select Update Driver If you are using an MXI controller right click PCI to PCI Bridge and select Properties from the shortcut menu to verify that the bridge is enabled...

Page 19: ...ni com community Support ni com support more about your products through ni com Located online at ni com manuals Located online at ni com gettingstarted RF Solutions ni com rf NI PXIe 5840 Specificati...

Page 20: ...information support phone numbers email addresses and current events Refer to the NI Trademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company nam...

Reviews: