background image

Environmental Characteristics

Temperature

Operating

0 °C to 55 °C for ≤ 58 W module operation

0 °C to 40 °C for > 58 W module operation

Storage

-40 °C to 71 °C

Humidity

Operating

10% to 90%, noncondensing

Storage

5% to 95%, noncondensing

Pollution Degree

2

Maximum altitude

2,000 m

Ventilation Clearance and Cooling

Cooling

Module

Forced air circulation (positive pressurization) through two 210 CFM fans

Secondary cooling

Forced air circulation (positive pressurization) through one 70 CFM fan

Power supply

Forced air circulation through two integrated fans

Minimum chassis cooling clearances

Top and sides

44.45 mm (1.75 in.)

Back

101.60 mm (4.00 in.)

Environmental Standards

This product meets the requirements of the following environmental standards for electrical equipment.
• IEC 60068-2-1 Cold
• IEC 60068-2-2 Dry heat
• IEC 60068-2-78 Damp heat (steady state)

Note

 

To verify marine approval certification for a product, refer to the product label or visit 

ni.com/certification

 and search for the certificate.

Power Requirements

Power Guidelines

Notice

 

This product is for use only with the Data Record System AD 500W DC Power Supply (NI part number 861354-01).

Power Specifications

Input voltage rating

1

9 V at 68 A

30 V at 19 A

Operating voltage range

9 VDC to 30 VDC

Maximum power consumption

PXI backplane power

12 V at 22.3 A

5 V

aux

 at 3 A

5 V at 26.5 A

3.3 V at 36 A

-12 V at 1.75 A

Total available output power

283 W

Maximum power consumption per PXI slot

58 W at 55 °C, 82 W at 40 °C

Main power disconnect

The installation must contain a suitable switch or circuit breaker for power

disconnect. It must be suitably located and easily reached, and marked as the

disconnect device for the equipment.

Required power cord

2.5 mm

2

 to 16 mm

2

 (14 AWG to 6 AWG) conductor

Select the proper conductor size based on power source and cable routing.

Ensure conductor insulation and cable construction are sufficient for the

application and adhere to applicable electrical codes. Ensure none of the

conductor is exposed.

1

Do not exceed the current rating of the branch circuit providing power to the chassis.

PXIe-1092DC Safety, Environmental, and Regulatory Information

  | 

© National Instruments Corporation

  | 