Physical Characteristics
Dimensions and Weight
Dimensions
Width
303.3 mm (11.94 in.)
Depth
463.6 mm (18.25 in.)
Height
177.1 mm (6.97 in.)
Weight (empty chassis with power supply installed)
11.7 kg (25.7 lbs)
DC Power Supply Field Wiring Specifications
Notice
Use only copper wire. For use in class 1 circuits only.
Note
Refer to the
Data Record System AD User Manual
for the power supply connection requirements.
Gauge
2.5 mm
2
to 16 mm
2
(14 AWG to 6 AWG) conductor
Wire strip length
12 mm
Temperature rating
60 °C minimum
Wires per terminal
1
Torque for screw terminals
1.7 to 1.8 N · m (15 to 15.9 lb · in.)
Single ferrule
Barrel length
12 mm (0.47 in.)
Maximum cross section of conductor plus ferrule
16 mm
2
(6 AWG)
Recommended crimping tool
Crimpfox 16 S crimping tool
Connector securement
Securement type
Screw locking
Torque for screw flanges
0.3 N · m (2.7 lb · in.)
Protective Earthing
When using the product with hazardous voltage PXIe modules or I/O (>30 VAC, 42.4 V
pk
, 60 VDC), connect the product to the protective earth terminal
before connecting to DC power.
Notice
The facility installation shall provide a means for connection to protective earth, and qualified personnel shall install a protective earthing
conductor from the protective earthing terminal on the product to the protective earth wire in the facility.
Notice
Use only copper wire to connect the protective earthing terminal of your product to the protective earth wire in the facility.
Protective Earth Terminal Wiring
Grounding wire gauge
2.1 mm
2
(14 AWG)
Ring lug
# 8
Protective earth terminal torque
1.13 N · m (10 lb · in.)
Export Compliance
This product is subject to control under the U.S. Export Administration Regulations (15 CFR Part 730 et. seq.) administered by the U.S. Department of
Commerce's Bureau of Industry and Security (BIS) (
) and other applicable U.S. export control laws and sanctions regulations. This product
may also be subject to additional license requirements of other countries' regulations.
Additionally, this product may also require export licensing before being returned to NI. The issuance of a Return Material Authorization (RMA) by NI does
for more information and to request relevant import classification codes (e.g. HTS), export classification codes (e.g. ECCN), and other
import/export data.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous
substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the
Commitment to the Environment
. This page contains the environmental
regulations and directives with which NI complies, as well as other environmental information not included in this document.
4
|
ni.com
|
PXIe-1092DC Safety, Environmental, and Regulatory Information