Page 12
WE 081313
Alarm
The Alarm symbol is shown when the unit encounters an issue that needs attention, the dis-
played alarm codes are explained below. The alarm code will remain displayed until corrected.
Alarm Codes
CPSM (Customer Preference Selection Mode)
Message
Cause
Solution
“E1”
Faulty Air Sensing Probe
Contact Customer Service
“AH1”
The air probe is sensing a
temperature that is 10° above
the set point
1. Allow time for the wine to reach the desired temperature.
2. Make sure all windows and doors are closed and have a proper seal.
3. Follow the procedures in the pre-installation instructions to test the unit for proper
cooling.
“AL1”
The air robe is sensing a tem-
perature that is 10° below the
set point
1. Make sure unit is not in cooling mode. (the snowflake symbol will not be lit)
2. Add heat to the room until the wine reaches the desired temperature.
Press and hold the set button for approximately 5 seconds to enter the CPSM menu.
Use the down arrow to access the following parameters.
PA2
No adjustable settings in this parameter.
tab
No adjustable settings in this parameter.
Rel
No adjustable settings in this parameter.
LOC
Change this parameter from “n” to “y” to lock the keyboard from changes to the set point.
CA1
Change the value to increase or decrease the temperature reading of the air sensor.(This process
re-calibrates the probe to the controller)Increasing the value by 1 means an increase in the tem-
perature reading by 1 degree. Decreasing the value by one means a decrease in the temperature
reading by 1 degree. This parameter can be ad- 12 degrees. If needed: Adjust this setting
to match your temperature sensor inside the cellar.