3  Installation 

READ THIS CAREFULLY BEFORE INSTALLATION! 

LEGGERE ATTENTAMENTE PRIMA 

DELL’INSTALLAZIONE!

 

A LIRE ATTENTIVEMENT AVANT L’INSTALLATION!

 

Before operating, read this document thoroughly and 

retain it for future reference. Non-respect of these 

instructions may reduce performances and safety of the 

devices and cause danger for people and property. The 

products must be installed, operated, serviced and 

maintained by qualified personnel in compliance with 

applicable standards and regulations. 

Don’t open the device, it does not contain replaceable 

components, the tripping of the internal fuse (if included) is 

caused by an internal failure. Don’t repair or modify the 

device, if malfunction or failure should occur during 

operation, send unit to the factory for inspection. No 

responsibility is assumed by Nextys SA for any 

consequences deriving from the use of this material. 

Prima dell’installazione, leggere attentamente questo 

documento istruzioni e conservarle per future consultazioni.  

L’inosservanza delle presenti istruzioni può compromettere le 

caratteristiche e la sicurezza del

l’apparecchio e causare 

pericolo per le persone e le cose. 

Il prodotto deve essere installato, utilizzato e riparato da 

personale qualificato e nel rispetto delle normative vigenti.  

Non aprire il prodotto, esso non contiene componenti 

sostituibili, il guasto del fusibile interno (se previsto) è causato 

da un guasto interno. Non tentare di riparare o modificare il 

prodotto, se durante il funzionamento si verificano guasti o 

anomalie, inviarlo al produttore per il controllo. 

Nextys SA non si assume nessuna responsabilità per 

qualunque conseguenza derivante dall’uso di questo materiale.

 

Lisez ces instructions avant l'installation, conservez ce 

manuel pour référence future. Défaut de se conformer à ces 

instructions peut affecter les caractéristiques et la sécurité 

du dispositif de danger et de causer aux personnes ou aux 

biens. Les produits doivent être installés, exploité et 

entretenus par personnel qualifié et en conformité avec les 

règlements. N'ouvrez pas le produit, il ne contient aucune 

pièce réparable, le déclenchement du fusible interne (le cas 

échéant) est causé par un défaut interne. Ne pas essayer de 

réparer ou modifier le produit ; si des défaillances se 

produisent pendant le fonctionnement ou les 

dysfonctionnements, le retourner au fabricant pour 

inspection. Nextys SA n'assume aucune responsabilité des 

conséquences éventuelles découlant de l'utilisation des 

produits.

 

CAUTION 

ATTENZIONE 

AVVERTISSEMENT

 

RISK OF BURNS, EXPLOSION, FIRE, ELECTRICAL 

SHOCK, PERSONAL INJURY. 

Never carry out work on live parts! Danger of fatal injury! 

The product’s enclosure may be hot, allow time for cooling 

product before touching it. Do not allow liquids or foreign 

objects to enter into the products.  

To avoid sparks, do not connect or disconnect the device 

before having previously turned-off input power and wait 

for internal capacitors discharge (minimum 1 minute). 

RISCHIO USTIONI, ESPLOSIONE, INCENDIO, SCOSSA, 

LESIONI GRAVI. 

Non effettuare mai operazioni sulle parti sotto tensione! 

Pericolo di lesioni letali! Il contenitore può scottare, lasciar 

quindi raffreddare il dispositivo prima di toccarlo. Non far 

entrare liquidi o oggetti estranei nel dispositivo. Per evitare 

scintille, non collegare o scollegare l'apparecchiatura prima di 

avere tolto tensione di ingresso e prima che sia avvenuta la 

scarica dei condensatori interni (min. 1 minuto). 

RISQUE DE BRULURES, EXPLOSION, INCENDIE, 

ELECTROCUTION, DOMMAGE AUX PERSONNES. 

Ne jamais effectuer des opérations sur les parties sous 

tension! Danger de mort! Le récipient peut produire des 

brulures, le laisser refroidir avant de toucher l'appareil. Ne 

faites pas pénétrer des liquides ou des corps étrangers dans 

l'appareil. Pour éviter des étincelles, ne pas connecter ou 

déconnecter l'équipement jusqu'à ce que vous avez 

supprimé la tension d'entrée et avant qu'elle n'ait lieu de 

décharge des condensateurs internes (minimum 1 minute).

 

 

Connections

 

 

 

 

 

Input Connection: 

 

Single phase 

 

L1 = Line 

 

N = Neutral 

 

I

 

= Earth ground

 

 

2 phases 

 

L1 = Phase 1 

 

L2 = Phase 2 

 

I

 

= Earth ground

 

 

DC: 

 

L1 = + Positive DC 

 

L2 = - Negative DC 

 

I

 

= Earth ground

 

 

ENABLE: 

(5…30Vdc)

 

 

+ = Positive DC 

 

- = Negative DC 

 

 

Output Connection: 
 

 

+ = Positive DC 

 

- = Negative DC 

 

Signaling: 

 

DC OK 

dry contact 24Vdc / 1A 

 

+ = NO 

 

- = COM 

 

RS-485 
 

 

 

 

PIN4 = TX/RX D1 

 

PIN5 = TX/RX D0 

 

PIN8 = GND 

 

(1)

 

AC input 

(2)

 

Enable input 

(3)

 

DC OK dry contact 

(4)

 

DC output (load) 

(5)

 

SET button menu 

(6)

 

UP button menu 

(7)

 

DOWN button menu 

(8)

 

Display 

(9)

 

RS-485 Comm. port 

Dimensions 

Distances

 

 

 

 

Dimensions 

mm 

80.0 

120.0 

112.0 

Distance

 


B

 

mm

 

20 
50

 

SBL200L_040-01-700-022-EH-1117

Summary of Contents for SBP200L

Page 1: ...SBP200L user manual rev6 Page 1 12 SBP200L 200W DIN Rail Programmable Output Voltage Power Supply User Manual POWERMASTER SBL200L_040 01 700 022 EH 1117...

Page 2: ...h the failure of the NEXTYS product could create a situation where personal injury or death may occur Should Buyer purchase or use NEXTYS products for any such unintended or unauthorized application B...

Page 3: ...al description 4 2 1 Operating modes 5 2 1 1 Operating mode 1 enable disable 5 2 1 2 Operating mode 2 external toggle 6 2 1 3 Operating mode 3 enable disable with timer 6 2 2 Interfaces 7 2 2 1 HMI Hu...

Page 4: ...as battery charger lead acid nickel lithium Can be used for LED lighting Can be paralleled for power or redundancy with external ORing module Up to 50 C operating temperature with no derating Suitable...

Page 5: ...or details of this parameter Output voltage 2 U2 See operating mode description for details of this parameter Output current 2 I2 See operating mode description for details of this parameter Delay Del...

Page 6: ...ith timer In operating mode 3 the device output is activated by the enable input The output toggles to the second set of voltage and current after a defined time Output deactivates when the ENABLE inp...

Page 7: ...ge Polarity 5s No store 2s Set Set Store Set 5s Output Voltage Modbus address 5s 2s Set Set Store Set 5s Output Voltage Baudrate 5s No store 2s Set Set Store Set 5s Output Voltage Modbus stop bits 5s...

Page 8: ...ster 3 4 6 16 1 1 2 1 active low polarity 2 active high polarity Modbus settings loaded on next startup Address 0x1100 4352 Hold register 3 4 6 16 1 1 247 Baudrate 0x1100 4353 Hold register 3 4 6 16 1...

Page 9: ...par un d faut interne Ne pas essayer de r parer ou modifier le produit si des d faillances se produisent pendant le fonctionnement ou les dysfonctionnements le retourner au fabricant pour inspection...

Page 10: ...ard until it hits the stop 4 Press against the bottom for locking 1 2 3 4 Dismounting 1 Pull down the slide clamp lever 2 Tilt the unit upward 3 Unhook the unit from the rail 1 2 3 Recommended connect...

Page 11: ...y recommended to provide external surge arresters SPD according to local regulations Environment Operating temperature Derating 40 C 70 C 5 95 r H non condensing Overtemperature protection Over 60Vdc...

Page 12: ...to the latest Reference standards if not expressly indicated through the official documents or files they have been tested through our internal pre compliance testing Consult directly on www nextys co...

Page 13: ...999 Kurt Stritzelberger Pewatron AG Edisonstra e 16 D 85716 Unterschlei heim Phone 49 89 260 52 80 Mobile 49 171 803 41 35 kurt stritzelberger pewatron com Postcode 32000 37999 Postcode 40000 79999 Ge...

Reviews: