1  Product description 

 

Use  latest  device  Documentation,  Software  and  Firmware  to  ensure  reliable  operation  of 

the system (downloadable from www.nextys.com).

 

 
The SBP200L is a microprocessor controlled adjustable power supply with the following features: 

  High efficiency and compact size

 

  Active PFC  

  Digital control 

 

Wide input voltage range 170…550Vac 

 

Wide output voltage range 24…120Vdc, user settable 

  User settable current limitation threshold 

  Remote ON/OFF or other remote control functions possible through ENABLE input 

  Modbus over RS-485 interface for control and monitoring 

  Multiple protections 

  2 user programmable voltage steps with settable duration 

  Can be used as battery charger (lead acid, nickel, lithium) 

  Can be used for LED lighting 

  Can be paralleled for power or redundancy (with external ORing module) 

  Up to 50°C operating temperature with no derating 

  Suitable for 

POWERMASTER

 software (available for Windows and Android) 

 

2  Functional description 

This unit works as a constant voltage source or a constant current source depending on the load. The 
output voltage is constant until the nominal current is reached. If more current is needed by the load 
the  device  reduces  the  output  voltage  to  ensure  the  nominal  current  is  not  exceeded.  The  U/I 
behavior of the output is shown on Figure 2, nominal voltage (Unom) and nominal current (Inom) are 
user  settable  and,  depending  on  the  operating  mode  (explained  below),  can  be  altered  by  the

 

ENABLE input. 
 

 

Figure 1: Front view 

Uout

Iout

Hiccu

p cycl

e

5V

Unom

Inom

 

Figure 2: Output voltage vs. Curent 

 

 

SBL200L_040-01-700-022-EH-1117

Summary of Contents for SBP200L

Page 1: ...SBP200L user manual rev6 Page 1 12 SBP200L 200W DIN Rail Programmable Output Voltage Power Supply User Manual POWERMASTER SBL200L_040 01 700 022 EH 1117...

Page 2: ...h the failure of the NEXTYS product could create a situation where personal injury or death may occur Should Buyer purchase or use NEXTYS products for any such unintended or unauthorized application B...

Page 3: ...al description 4 2 1 Operating modes 5 2 1 1 Operating mode 1 enable disable 5 2 1 2 Operating mode 2 external toggle 6 2 1 3 Operating mode 3 enable disable with timer 6 2 2 Interfaces 7 2 2 1 HMI Hu...

Page 4: ...as battery charger lead acid nickel lithium Can be used for LED lighting Can be paralleled for power or redundancy with external ORing module Up to 50 C operating temperature with no derating Suitable...

Page 5: ...or details of this parameter Output voltage 2 U2 See operating mode description for details of this parameter Output current 2 I2 See operating mode description for details of this parameter Delay Del...

Page 6: ...ith timer In operating mode 3 the device output is activated by the enable input The output toggles to the second set of voltage and current after a defined time Output deactivates when the ENABLE inp...

Page 7: ...ge Polarity 5s No store 2s Set Set Store Set 5s Output Voltage Modbus address 5s 2s Set Set Store Set 5s Output Voltage Baudrate 5s No store 2s Set Set Store Set 5s Output Voltage Modbus stop bits 5s...

Page 8: ...ster 3 4 6 16 1 1 2 1 active low polarity 2 active high polarity Modbus settings loaded on next startup Address 0x1100 4352 Hold register 3 4 6 16 1 1 247 Baudrate 0x1100 4353 Hold register 3 4 6 16 1...

Page 9: ...par un d faut interne Ne pas essayer de r parer ou modifier le produit si des d faillances se produisent pendant le fonctionnement ou les dysfonctionnements le retourner au fabricant pour inspection...

Page 10: ...ard until it hits the stop 4 Press against the bottom for locking 1 2 3 4 Dismounting 1 Pull down the slide clamp lever 2 Tilt the unit upward 3 Unhook the unit from the rail 1 2 3 Recommended connect...

Page 11: ...y recommended to provide external surge arresters SPD according to local regulations Environment Operating temperature Derating 40 C 70 C 5 95 r H non condensing Overtemperature protection Over 60Vdc...

Page 12: ...to the latest Reference standards if not expressly indicated through the official documents or files they have been tested through our internal pre compliance testing Consult directly on www nextys co...

Page 13: ...999 Kurt Stritzelberger Pewatron AG Edisonstra e 16 D 85716 Unterschlei heim Phone 49 89 260 52 80 Mobile 49 171 803 41 35 kurt stritzelberger pewatron com Postcode 32000 37999 Postcode 40000 79999 Ge...

Reviews: