SBP200L
user manual rev6
Page 6/12
2.1.2
Operating mode 2 (external toggle)
In operating mode 2 the device output
toggles between 2 sets of voltage and
current through the ENABLE input.
Parameters:
OP
2
U1
Nominal voltage with enable 1
I1
Nominal current with enable 1
U2
Nominal voltage with enable 0
I2
Nominal voltage with enable 0
Del
Not used
Pol
Lo or Hi
2.1.3
Operating mode 3 (enable/disable with timer)
In operating mode 3 the device output is
activated by the enable input. The output
toggles to the second set of voltage and
current after a defined time. Output
deactivates when the ENABLE input is
disabled.
Parameters:
OP
3
U1
First nominal voltage
I1
First nominal current
U2
Second nominal voltage
I2
Second nominal current
Del
Delay for switching between
U1/I1 to U2/I1
Pol
Lo or Hi
Unom
Tim e
U1
Tim e
Tim e
I nom
Enable
U2
I 1
I 2
1
0
0
0
Figure 4: Operating mode 2
Unom
Tim e
U1
Tim e
Tim e
I nom
Enable
U2
I 1
I 2
1
0
0
0
Del
Del
Del
Del
Figure 5: Operating mode 3