___________________________________________________________________________________________________
NEXO NX242 DIGITAL TDcontroller Service manual rev100606
P.10
Only if you have a Philips component, you have to remove the added capacitor
You can unsolder the capacitor, or simply cut the legs as near as possible to the legs of the Philips component.
If you have a Texas component, you must have the capacitor between the pin 2 and the pin 8 of U5401.
Once this operation is finished, replace the cover of the NX242, with all of the screws, as they are important for
the shielding of the digital section of the controller. When you power up the unit again, it should boot normally,
and none of your settings should be lost. Check that the noise has disappeared on all the outputs (be sure to
check the input A of the controller).