8.2 GEO M1210 & GEO M1220
8.2.1 System specifications
GEO M1210
(without CDD
TM
)
GEO M1210
(with CDD
TM
)
GEO M1220
(without CDD
TM
)
GEO M1220
(with CDD
TM
)
GEO M12 WITH NEXO TDCONTROLLER SETUP
Frequency Response @-6 dB
50 Hz to 20 kHz
Sensitivity 1W@1m
105 dB SPL Nominal
Peak SPL@1m
140 dB
Vertical Dispersion
10°
20°
Horizontal Dispersion
80°
120°
80°
120°
Passive Crossover Frequency
1.1 kHz
Nominal Impedance
Active mode : (8
Ω LF + 16 Ω HF) / Passive mode : 8 Ω
Recommended Power
Active mode : (1250 Watts LF + 625 Watts HF) / Passive mode : 1250 Watts
PRODUCT FEATURES
LF Component
1 x 12” 8 Ohms long excursion Neodymium driver with PDD
TM
HF Component
1 x 3” voice coil 1.4” throat driver on a BEA/FEA optimized HR Wavesource
TM
Height x Width x Depth
370 mm x 700 mm
x 446 mm (14.6” x 27.6” x 17.6”)
Weight: Net
34 kg (75 lb)
Connectors (Touring version)
2 x NL4, 4 poles connectors (1+/1- Through, 2+/2- GEO M12 in passive mode,
1+/1- LF, 2+/2- HF in active mode)
Connectors (Install version)
2 x Cable gland with 4 cores connectors
Active / Passive mode selection
Ruggedized, recessed, waterproof 2 positions switch
Construction
Lightweight Polyurethane Composite
Fittings
2 x Side handles hori back grip
Front Finish (Touring version)
Steel front grill + back mesh
Front Finish (Install version)
Acoustic fabric fitted front grill
Operating temperature range
0°C
– 40°C (32°F – 104°F)
Storage temperature range
-20°C
– 60°C (-4°F – 140°F)
Recommended powering solution
NXAMP4x4 Powered TD controller: up to 3 x GEOM12 in passive mode per
channel
Optional powering solution
NXAMP4x2mk2 Powered TD controller: 1 x GEOM12 in passive mode per
channel
NXAMP4x1mk2 Powered TD controller (Bridged): up to 2 x GEOM12 in passive
mode per channel
8.2.2 Dimensions (mm/inches)
Summary of Contents for GEO M12 Series
Page 13: ...CONNECTION DIAGRAMS Page 13 90 3 3 GEO M12 passive mode and MSUB18 NXAMP4x1mk2 Bridge Stereo ...
Page 14: ...Page 14 90 CONNECTION DIAGRAMS 3 4 GEO M12 passive mode NXAMP4x2mk2 3 5 MSUB18 NXAMP4x2mk2 ...
Page 15: ...CONNECTION DIAGRAMS Page 15 90 3 6 GEO M12 passive mode and MSUB18 NXAMP4x2mk2 ...
Page 16: ...Page 16 90 CONNECTION DIAGRAMS 3 7 GEO M12 passive mode NXAMP4x4 ...
Page 17: ...CONNECTION DIAGRAMS Page 17 90 3 8 GEO M12 active mode NXAMP4x4 ...
Page 18: ...Page 18 90 CONNECTION DIAGRAMS 3 9 MSUB18 Omni Mode NXAMP4x4 ...
Page 19: ...CONNECTION DIAGRAMS Page 19 90 3 10 MSUB18 Cardio Mode NXAMP4x4 ...
Page 20: ...Page 20 90 CONNECTION DIAGRAMS 3 11 GEO M12 passive mode and MSUB18 NXAMP4x4 ...
Page 76: ...Page 76 90 TECHNICAL SPECIFICATIONS 8 3 7 VNT MNSTKM12 Parts X1 Dimensions Weight 3 kg 6 6 lb ...
Page 79: ...TECHNICAL SPECIFICATIONS Page 79 90 8 3 10 GMT FLGM12 Parts X1 Dimensions Weight 1 kg 2 2 lb ...
Page 82: ...Page 82 90 TECHNICAL SPECIFICATIONS 8 3 13 MST COVMSUB18 Parts X1 Weight 2 2 kg 5 lb ...
Page 83: ...TECHNICAL SPECIFICATIONS Page 83 90 8 3 14 MST COV2MSUB18 Parts X1 Weight 3 5 kg 7 7 lb ...