2.3 Cabling
NEXO recommends the exclusive use of multi-conductor cables to connect the system: the cable kit is
compatible with all the cabinets, and there is no possible confusion between LF, MF and HF sections.
Cable choice consists mainly of selecting cables of the correct sectional dimension (size) in relation to
the load resistance and the cable length. Too small a cable section will increase both its serial resistance
and its capacitance; this reduces the electrical power delivered to the loudspeaker and can also induce
response (damping factor) variations.
For a serial resistance less or equal to 4% of the load impedance (damping factor = 25), the recommended
cable length is given by:
L
max
= Z x S
S in mm
2
, Z in Ohm, L
max
in meters
The table below indicates these values, for 3 common sizes.
Load Impedance (
)
2
3
4
6
8
Cable section
Recommended Cable Length
1,5 mm² (AWG #14)
3m/10ft
4.5m/13ft 6m/20ft
9m/30ft
12m/39ft
2,5 mm² (AWG #12)
5m/16ft
7.5m/23ft 10m/33ft 15m/49ft 20m/66ft
4 mm² (AWG #10)
8m/26ft
12m/39ft 16m/52ft 24m/79ft 32m/105ft
Maximum allowed length is 4 times recommended length.
Example:
GEO M12 module has a 8
nominal impedance in passive mode. When connecting 4 modules in parallel,
total load impedance become 2
.
Recommended length for 4mm
2
/ (AWG#10) is 8m / 26ft, maximum allowed length is 32m / 105ft.
IMPORTANT
Long speaker cables induce capacitive effects
– up to hundreds of pF depending on the
quality of the cable - with a low-pass effect on high frequencies. If long speaker cables
must be used, ensure that they do not remain coiled while in use.
2.4 GEO M12 & MSUB18 recommended amplification
NEXO TD Controllers
Recommended amplification
NXAMP4x1mk2 Powered Controller Bridged Stereo mode
(2x2.6kW/4
)
2 x GEO M12 in passive mode per bridged channel
1 x MSUB18 per bridged channel
NXAMP4x2mk2 Powered Controller 4 channels mode
(4x2.5kW/2
)
1 x GEO M12 in passive mode per channel
1 x MSUB18 per channel
NXAMP4x4 Powered Controller 4 channels mode
(4x4kW/2
)
3 x GEO M12 in passive mode per channel
3 x GEO M12 in active mode: 2 channels
2 x MSUB18 per channel
2.5 GEO M12 & MSUB18 setups on NEXO TD Controllers
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
Summary of Contents for GEO M12 Series
Page 13: ...CONNECTION DIAGRAMS Page 13 90 3 3 GEO M12 passive mode and MSUB18 NXAMP4x1mk2 Bridge Stereo ...
Page 14: ...Page 14 90 CONNECTION DIAGRAMS 3 4 GEO M12 passive mode NXAMP4x2mk2 3 5 MSUB18 NXAMP4x2mk2 ...
Page 15: ...CONNECTION DIAGRAMS Page 15 90 3 6 GEO M12 passive mode and MSUB18 NXAMP4x2mk2 ...
Page 16: ...Page 16 90 CONNECTION DIAGRAMS 3 7 GEO M12 passive mode NXAMP4x4 ...
Page 17: ...CONNECTION DIAGRAMS Page 17 90 3 8 GEO M12 active mode NXAMP4x4 ...
Page 18: ...Page 18 90 CONNECTION DIAGRAMS 3 9 MSUB18 Omni Mode NXAMP4x4 ...
Page 19: ...CONNECTION DIAGRAMS Page 19 90 3 10 MSUB18 Cardio Mode NXAMP4x4 ...
Page 20: ...Page 20 90 CONNECTION DIAGRAMS 3 11 GEO M12 passive mode and MSUB18 NXAMP4x4 ...
Page 76: ...Page 76 90 TECHNICAL SPECIFICATIONS 8 3 7 VNT MNSTKM12 Parts X1 Dimensions Weight 3 kg 6 6 lb ...
Page 79: ...TECHNICAL SPECIFICATIONS Page 79 90 8 3 10 GMT FLGM12 Parts X1 Dimensions Weight 1 kg 2 2 lb ...
Page 82: ...Page 82 90 TECHNICAL SPECIFICATIONS 8 3 13 MST COVMSUB18 Parts X1 Weight 2 2 kg 5 lb ...
Page 83: ...TECHNICAL SPECIFICATIONS Page 83 90 8 3 14 MST COV2MSUB18 Parts X1 Weight 3 5 kg 7 7 lb ...