TROUBLE SHOOTING 

 

 

 

Problem    Possible Causes                    Correction  

 

 

Purge gas line and repeat ignition operation   

 

Check gas pressure   

 

Check gas passage way   

 

 

 

Reset the Heater keep in vertical position   

 

Replace thermocouple   

 

Clean thermocouple contact   

 

Wait a minute repeat ignition operation   

 

Replace gas valve   

 

Tighten connection or replace thermocouple   

 

 

Contact a qualified service person 

 

 

 

 

Check gas supply pressure   

 

Clean burner inside and outside   

 

Turn control knob to ‘HIGH’ position 

 

 

Air in gas line   

 

Low gas pressure   

 

Blockage in gas line   

 

   

 

Tilt switch in trip angle/OFF position   

 

Bad thermocouple   

 

Corrosion of thermocouple contact   

 

Safety interlock is triggered   

 

Bad gas valve   

 

Thermocouple connection loose at gas 

control or damaged   

 

Pilot flame not touching the   

thermocouple 

   

 

 

Low gas pressure   

 

Blockage in burner   

 

Control knob not in ‘HIGH’ position 

 

Pilot won’t   

light

 

 

 

 

Pilot won’t   

stay lit

 

 

 

 

 

 

 

 

 

 

 

 

Main burner   

won’t light 

 

 

 

 

 

 

 

Page 12 

 

Summary of Contents for T-005

Page 1: ...RTS PRECAUTIONS ASSEMBLY INSTRUCTIONS GAS REQUIREMENTS LEAK TESTING LOCATING HEATER FOR USE LIGHTING INSTRUCTION IGHTING INSTRUCTION 1 2 3 4 7 8 9 10 11 12 13 14 SHUTDOWN INSTRUCTION SHUTDOWN INSTRUCTION STORAGE BURNER REMOVAL STORAGE BURNER REMOVAL TROUBLE SHOOTING TROUBLE SHOOTING EXPLODED VIEW EXPLODED VIEW WARRANTY WARRANTY PLEASE CONTACT 1 800 913 8999 FOR ASSISTANCE DO NOT RETURN TO PLACE OF...

Page 2: ...ce can cause severe property damage or serious injury or death Please read the installation operation maintenance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY If you smell gas Shut off gas to appliance Extinguish any open flame If odor continues immediately call your gas supplier For your safety Do not store or use gasoline or other flammable vapor and liqu...

Page 3: ...y with Tank Cover Post Burner Assembly Emitter Assembly Emitter Screen 2 Reflector Reflector Dome Cap Hardware Bag Tank Enclosure 3 16 Screw 3 Emitter Base 3 16 Screw 3 Emitter Screen 3 16 Screw 4 Reflector cap nut 1pc For Service Questions Replacement parts or other Assistance Please call VAI Customer Service Hotline at VAI 145 Brea Canyon Road Walnut CA 91789 800 913 8999 Page 2 ...

Page 4: ... if any of the following exists 1 The smell of gas in conjunction with extreme yellow tipping of the burner flames 2 The heater does not reach temperature 3 The burner makes popping noise during use a slight popping noise is normal when the burner is extinguished Children and adults should be aware of hazards of high surface temperature and shall stay away to avoid burns of clothing ignition Young...

Page 5: ...ith corresponding holes in emitter bottom fasten three 3 16 truss head screws to the emitter base STEP 1 Connect Top Portion to Tank Enclosure Place top portion on of tank enclosure Insert the three 3 16 truss head screws in three holes until tight ASSEMBLY INSTRUCTION Page 4 ...

Page 6: ...en with two truss head 3 16 screws to the post b Hook up two emitter screen together c Screw the other emitter screen on post with two truss head 3 16 screws STEP 4 Attach the Reflector Insert threaded end of final cap nut through cap and screw into center of dome until secure Page 5 ...

Page 7: ... tank enclosure door to locate the regulator Rotate gas pressure regulator outwards Attach propane gas to regulator inlet fitting by turning the propane gas clockwise The LP Gas supply cylinder must be disconnected when this appliance is not in use Disconnect it by turning the propane gas counter clockwise Page 6 ...

Page 8: ...artment of Transportation A dented rusted or damaged propane tank may be hazardous and should be checked by your tank supplier Never use a gas tank with a damaged valve connection Leak Testing Make a soap solution of one part liquid detergent and one part water The solution can be applied with a spray bottle brush or rag Soap bubbles will appear where a leak is present Once the gas cylinder is sec...

Page 9: ...g of outdoor patios decks spas pool and working areas The minimum clearances to combustible construction shown in above must be maintained at all times The installation must conform to local codes or in the absence of local codes with the standard for the storage and handling of liquid petroleum gases In the US use ANSI NFPA58 on National Fuel Gas Code ANSI Z223 1998 In Canada use National Standar...

Page 10: ...r is connected to the gas tank Check the connection to ensure they are tight and leak proof C Check for leaks by applying soapy water to the tank and regulator connections D Push and turn the gas control knob to HIGH postion for several seconds It might take 2 or 3 trials to light the burner Warning Keep a safe distance of at least 3 feet when attampting to ignite unit Avoid inhaling fumes emitted...

Page 11: ...er should be turned off immediately and the heater should not be operated again until repairs are made FIGURE 2 NORMAL FLAME POSITION 2 1 0 RELIGHTING A Turn the control knob to off position B Wait five 5 minutes before attempting to relight burner C Repeat To Light Step D on prior page SHUT DOWN INSTRUCTIONS A Turn control knob clockwise to OFF position The burner may make a slight popping sound ...

Page 12: ...d transit these webs or nests can lead to a gas flow obstruction which could result in afire on and around the burner tubes This type of fire is known as FLASH BACK and can cause serious damage to your patio heater and create an unsafe operating condition for the user Although an obstructed burner tube is not the only cause of FLASH BACK it is the most common cause and frequent inspections and cle...

Page 13: ...ualified service person Check gas supply pressure Clean burner inside and outside Turn control knob to HIGH position Air in gas line Low gas pressure Blockage in gas line Tilt switch in trip angle OFF position Bad thermocouple Corrosion of thermocouple contact Safety interlock is triggered Bad gas valve Thermocouple connection loose at gas control or damaged Pilot flame not touching the thermocoup...

Page 14: ...NUT DOME CAP REFLECTOR EMITTER GRID MAIN BURNER ASSEMBLY EMITTER BASE EMITTER SCREEN 3 16 TRUSS HEAD SCREW POST ORIFICE GAS PIPE 3 16 SCREW SHROUD COVER PILOT ASSEMBLY GAS VALVE CONTROL REGULATOR TILT SAETY SWITCH VALVE KNOB CYLINDER HOUSING DOOR DOOR LATCH CYLINDER HOUSING PANEL BASE ASSEMBLY RUBBER BAND WEIGHTED BASE Q TY 1 1 1 1 1 1 2 17 1 1 1 7 1 1 1 1 1 1 1 1 1 1 1 Page 13 ...

Page 15: ...ary to operating instructions or alteration by any person other than our factory service center The warranty period is not extended by such repair or replacement Warranty claim procedure If you require service or parts for your Mini Table Top Heater please contact our Warranty Service Center for factory direct assistance Our hours of operation are 8 AM to 5 PM PST Our number is 1 800 913 8999 and ...

Reviews: