![Nexgrill T-005 Installation, Operation & Maintenance Instructions Manual Download Page 8](http://html.mh-extra.com/html/nexgrill/t-005/t-005_installation-operation-and-maintenance-instructions-manual_1681857008.webp)
GAS REQUIREMENTS & LEAK TESTING
Gas Requirements
The gas pressure regulator provided with this heater must be used. This regulator is set for L.P
Propane units at 10.0” W.C.
Maximum inlet pressure to propane regulator must not exceed 100 PSI.
The pressure regulator provided with this heater must be used. This regulator is set for L.P. /
Propane units at 10.0” W.C.
The propane tank must be constructed and marked in accordance with the specifications for LP gas
cylinders of the US Department of Transportation.
A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank
supplier. Never use a gas tank with a damaged valve connection.
Leak Testing
Make a soap solution of one part liquid detergent and one part water. The solution can be
applied with a spray bottle, brush or rag. Soap bubbles will appear where a leak is present.
Once the gas cylinder is securely attached make certain the control valve knob is in the ‘OFF’
position then check for leaks.
If a leak is present detach the gas cylinder, tighten any leaking fitting, re-attached the gas
cylinder and recheck.
Warning:
Never connect an unregulated gas supply to the heater.
!
Page 7