WIFI/Wireless User Manual V1 2019
7
Ref: Description
Range
Default
A1
Temperature Calibration -9-+9
℃
0.5
℃
A2
Switching Differential of
the Built in Sensor
0.5-2.5
℃
1
℃
A3
Switching Differential of
the External Sensor
1-9
℃
2
℃
A4
Child Lock
0: half lock 1: full lock
0
A5
Max temperature of the
External Sensor
1. 35
℃
-70
℃
2. When the setting temperature is lower
than 35
℃
the screen displays
【
--
】
, cancel
highest temp protection
-
A6
Min temperature of the
External sensor (anti-
freeze protection)
1. 1-10
℃
2. When setting temperature is higher than
10
℃
, screen displays
【
--
】
,
cancel anti-
freeze protection.
5
℃
A7
Max Temperature Setting 1-10
℃
5
℃
A8
Min Temperature Setting 20-70
℃
35
℃
A9
Descaling function
0: Close the descaling function
1: Open the descaling function
The function works for 3 minutes every non-
operating 100 hours
0
AA
Power off Memory
0: Stay last state
1: Electricity turn off
2: Electricity turn on
0
AB
Weekly Programmable
Function
P1: 5+2 days
P2: 6+1 days
P3: 7 days
P1
AC
Factory defaults
Display A o, long press the
button until it
shows the whole screen
-
Setting IP Code
In power off state, long press the
button for 3-5 seconds and you will enter into the
advanced setting mode.
You then short press the
button to switch and confirm and use the and
buttons to adjust the options.
After you finish setting, wait for 5 seconds and it will save the setting and exit.