SYMPTOM

PROBABLE CAUSE

SOLUTION

No voltage from Dancer Position Sensor.

No power to the Dancer Position sensor

Turn on the power to the Dancer Position 
Controller.  Connect the Dancer Position 
Sensor according to Figure 6.

Input power polarity is backwards

Check polarity of the power supply.  Con-
nect the Dancer Position Sensor accord-
ing to Figure 6.

Dancer Position Sensor output does not 
change.

No power to the Dancer Position Sensor

Turn on the power to the Dancer Position 
Controller.  Connect the Dancer Position 
Sensor according to Figure 6.

Dancer Position Sensor misaligned

Align the Dancer Position Sensor accord-
ing to Figure 2 for Mid Point of Output 
and according to the instructions in the 
INSTALLATION and ADJUSTMENT sec-
tions.

Dancer arm exceeds the capacity of the 
sensor.

Switch to a DPS60A or restrict the swing 
for the Dancer arm. Refer to SPECIFICA-
TIONS

Position Sensor Signal is erratic with no 
dancer arm movement.

Electrical noise interfering with sensor.

Connect the shield directly to earth 
ground.  If noise persists, ensure the 
sensor shaft has a low impedance path to 
earth ground.  See WIRING INSTALLA-
TION GUIDE

Dancer Position Sensor output voltage is 
not changing through the full 30 degree 
or 60 degree range.

Dancer Position Sensor misaligned

Refer to Figure 2 for proper alignment 
of the sensor.  The shaft marking should 
point toward the cable for mid-travel posi-
tion of the dancer arm.

Summary of Contents for 964518

Page 1: ...1 FORM NO L 21261 B 0214 Dancer Position Sensor DPS60A Dual WEB CONTROL PRODUCTS User Manual...

Page 2: ...ce until the machinery into which it is to be incorporated has been declared in conformity with the applicable provisions of the Directive Read this manual carefully before installation and operation...

Page 3: ...BLE OF CONTENTS Introduction 4 Installation 4 Direct Connection 4 Coupling Connection 5 Electrical Connections 6 Adjustment 6 Troubleshooting 7 Mounting Dimensions 8 Parts List 9 Replacement Parts 9 S...

Page 4: ...lowing for flexibility in the mounting position See Figure 7 4 Attach Dancer Position Sensor Item 1 to one of the three hole configurations on the Bracket Item 3 with two shorter Pan Head Screws Item...

Page 5: ...g See figure 4 7 Measure the distance from the bottom of the Bracket Item 3 to the machine s side frame Fabricate a spacer block to make up the distance between the Bracket and the machine s side fram...

Page 6: ...d in its mid travel position the sensor output should be approximately 5 VDC If it is not then slightly loosen the sensor s fasteners and rotate the sensor until the voltage reading is 5 VDC Refer to...

Page 7: ...the Dancer Position Sensor accord ing to Figure 2 for Mid Point of Output and according to the instructions in the INSTALLATION and ADJUSTMENT sec tions Dancer arm exceeds the capacity of the sensor S...

Page 8: ...FORM NO L 21261 B 0214 8 MOUNTING DIMENSIONS DANCER POSITION SENSOR Figure 9 9 9 390 48 6 1 91...

Page 9: ...ts through your local Nexen Distributor DPS60A DUAL Product Number 964518 Supply Voltage 24 6 VDC Output Voltage 0 10VDC max angular rotation Reverse Polarity Protection 30VDC maximum Temperature 40o...

Page 10: ...OTHER BREACH OF CONTRACT NEGLIGENCE OR OTHER TORT OR OTHERWISE EVEN IF NEXEN SHALL HAVE BEEN ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH POTENTIAL LOSS OR DAMAGE For all of the purposes hereof t...

Reviews: