2. Product operation
2.1.
Smoke detection
Product is working locally as a standalone smoke alarm by activating its sounder and LED when
smoke is detected.
A “Smoke Alarm” message
(Refer to section 4.4 Smoke alarm status) is sent twice at 10 seconds
intervals after the smoke alarm activation occurs. Then, the message is sent once every minute
until smoke alarm deactivation. This event will also trigger a message sent twice at 10 seconds
intervals.
2.2.
Push button
Short press to stop or pause your product
Short press is used for pausing or stopping the smoke alarm. Pausing the alarm helps to control a
pending false alarm in advance (e.g.: smoke or steam when cooking, use of candles or incense,
cigarette smoking, etc.). After 9 minutes, your product automatically resumes normal operation.
Long press to test your product
To test your alarm, press the button (> 3 seconds) until the alarm sounds then release. If the test
does not work, the detector probably detected an operating defect.
A “Smoke alarm” message is sent to indicate the beginning and the e
nd of the test (Refer to
section 4.4 Smoke alarm status).
“Real Time”
message containing temperature, humidity and air
quality is also generated (Refer to section 4.6 Real Time Data).
Multiple press
A multiple press (3 times) generates an OTAA join request.